Figure 13.16 Combustible Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
TOP VIEW
3-1/4 in. Min.
2-3/4
in. Min.
1/2 in.
Min.
Unlimited
1 in.
Max.
FIREPLACE
OPENING
Note: Clearance from opening to perpendicular wall.
C. Facing Material
Metal front faces may be covered with non-combustible
materials only.
• Facing and/or nishing materials must not interfere with
air ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the nished wall and appliance top
and sides using a 300 °F minimum sealant. Refer to
Figure 13.17.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as speci ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
0 in.
0 in.
0 in.
Finish wall material may be
combustible - Top and Sides
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
Figure 13.17 Noncombustible Facing Diagram
Figure 13.19 Overlap Fit Door
Figure 13.18 Folio Door and Aero
DOOR FIT
FINISH MATERIAL
MAXIMUM
THICKNESS
SEE FIGURE
Aero Inside Any 13.18
Folio Inside Any 13.18
Arcadia
Overlap 1 inch 13.19
Inside Any 13.20
Halston
Overlap 1 inch 13.19
Inside 1 inch - 2 inch 13.21
Chateau
Overlap 1 inch 13.19
Inside Any 13.20
Valencia
Overlap 1 inch 13.19
Inside Any 13.20
Galleria
Overlap 1 inch 13.19
Inside 1 inch - 2 inch 13.21
D. Finishing Material
Only doors certi ed for use with this appliance model may
be used. Contact your dealer for a list of doors that may
be used. Once you have determined what kind of door
and nishing material is going to be used on the replace,
you may use the table below which shows the door mod-
els and the nishing material thickness allowed. For an
inside t there is an available template to assist with siz-
ing the nishing material.
Stop nishing material ush with opening.
FINISHING MATERIAL
4 IN. MAXIMUM THICKNESS
DOOR
FINISHING MATERIAL
4 IN. MAXIMUM THICKNESS
1 in. MAX
FINISHING MATERIAL
(TOP EDGE)
DOOR
FRONT FACE OF FIREPLACE
Finishing materials 1 inch maximum thick.
Stop nishing material ush with opening.
ST-36TRB-IPI
DOOR FIT
FINISH MATERIAL
MAXIMUM
THICKNESS
SEE FIGURE
Aero Inside Any 13.22
Chateau Inside Any 13.22
Arcadia Inside Any 13.22
PIER-36TRB-IPI