Hearth and Home Technologies PIER-36TRB-IPI Indoor Fireplace User Manual


 
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. B • 10/0820
C
A
B
D
Figure 5.3 Clearances to Combustibles PIER-36TRB-IPI
G
F
I
I
E
H
* Adjust framing dimensions for interior sheathing (such as sheetrock)
PIER-36TRB-IPI
ABCDEFGHI
DVP Pipe SLP Pipe
Rough
Opening
(Height)
DVP Pipe*
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Ends of
Appliance
Sides of
Appliance
Rough
Opening
(Width)
Rough
Opening
(Width)
Rough
Opening
(Depth)
Inches
10 8-5/8 38-1/8 23 40 31-5/8 0 0 1/2 36
Millimeters
254 219 968 584 1016 803 0 0 13 914
C
A
B
D
Figure 5.4 Clearances to Combustibles LCOR-36TRB-IPI and RCOR-36TRB-IPI
* Adjust framing dimensions for interior sheathing (such as sheetrock)
RCOR-36TRB-IPI
LCOR-36TRB-IPI
ABCDEFGHI
DVP Pipe SLP Pipe
Rough
Opening
(Height)
DVP Pipe*
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Ends of
Appliance
Sides of
Appliance
Rough
Opening
(Width)
Rough
Opening
(Width)
Rough
Opening
(Depth)
Inches
10 8-5/8 38-1/8 24 40 31-5/8 0 0 1/2 36
Millimeters
254 219 968 610 1016 803 0 0 13 914
G
F
I
I
E
H
H