Hearth and Home Technologies EL36 Series Indoor Fireplace User Manual


 
39
IMPORTANT! Hearth extension design must be
determined before installation of replace.
Floor
Noncombustible
Framing Material
Noncombustible
Finishing Material
Protective Metal
Hearth Strips
1/2 in. Micore
or equivalent
insulation
Noncombustible
Material
Figure 11.3 Raised Platform Hearth Extension Detail
Raised Hearth Extension Framing
WARNING! Risk of Fire. A raised hearth extension built
ush with the replace opening (Figure 11.3) or less than
4 in. (102 mm) below the replace opening requires the
replace be installed on a non-combustible surface.
The hearth framing must be constructed of non-combus-
tible materials (Figure 11.2) and placed on 1/2 in. Micore,
or equivalent material (Figure 11.4). When creating the
platform, allow for the thickness of the non-combustible
nishing materials (Figure 11.5).
Noncombustible
Framing Material
1/2 in. Micore or
equivalent insulation
Figure 11.4 Raised Platform Hearth Extension-Framing Materials
2 in. (51 mm) of the Protective
Metal Hearth Strip is required
under the front of the fireplace
Tile, stone or other
non-combustible material
Floor constructed of wood or
other combustible material
Fireplace
Opening
4 in.
(102 mm) min.
Continuous, non-
combustible sealant
1/2 in. Micore Hearth
Extension (or
equivalent insulation)
See Table 11.2.
Figure 11.2 Hearth Extension Construction
B
A
C
C
D
4 in. (102 mm)
minimum between
bottom of fireplace opening
and finished surface of hearth extension
Figure 11.1 Hearth Extension Dimensions
Model # A B C D
EL36
in. 36 52 8 16
mm 914 1321 203 406
EL42
in. 42 66 12 20
mm 1067 1676 305 508