Hearth and Home Technologies EL36 Series Indoor Fireplace User Manual


 
18
6
6
Framing & Clearances
G
F
E
A
C
Across a
corner
H
As a
room
divider
D
48 in.
(1219 mm)
minimum
A
Along a wall
A
B
5/8 in. (16 mm) all
configurations
H
1/2 in. (13 mm) min. air
space from fireplace to
combustible materials.
Note:
Note:
In addition to these
framing dimensions,
also reference the
following sections:
• Clearances (Section
6.B.)
• Mantel Projections
(Section 11.E.)
• Fireplace Dimensions
(Section 13.A.)
H
B
In an exterior chase
or projecting into a
garage
A
Note: Measurements are FRAMING dimensions only and do
not include drywall either in the cavity or on the interior walls.
I
I
Figure 6.1 Fireplace Locations (Framing dimensions shown)
A. Select Fireplace Location
Model A B C D E F G H I
EL36
inches 42 50 67 7/8 59 1/2 34 14 48 21 1/2 12 in. (305 mm)
Minimum from FP
opening to any
perpendicular wall.
mm 1067 1270 1724 1511 864 356 1219 546
EL42
inches 48 56 73 7/8 65 1/2 37 1/4 14 52 1/4 21 1/2
mm 1219 1422 1876 1664 946 356 1327 546
Heatilator • EL36/EL42 • 4044-132 • Rev V • 11/08