Hearth and Home Technologies COLBAY-INS Indoor Fireplace User Manual


 
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev. H • 10/0810
Kit contents: Replacement ori ce; replacement pilot
injector; valve regulator; conversion label.
Tools required: Power drill (a 90° handle is helpful); #2
Phillips bit; 5/32 in. (4 mm) Allen wrench; 5/8 in. (16 mm)
open end wrench.
Remove logs and refractory support covers from the
burner pan. Remove the two screws that secure the
burner pan to the burner support with the screwdriver. Lift
burner up and out of the rebox opening.
Note: Gas conversions should only be performed by a
quali ed service person, and/or where required by state
and local codes, licensed installer/service technician. In
the Commonwealth of Massachusetts, installation must be
performed by a licensed plumber or gas tter.
B. Converting to LP Gas
A. Fuel Conversions
Before making gas connections ensure that appliance be-
ing installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to
meet the appliance and locality needs must be made by
a quali ed technician using Hearth & Home Technologies
speci ed and approved parts.
6
6
Gas Information
Figure 6.1
Figure 6.2
Figure 6.3
Note: Do not remove retaining clip from the pilot hood.
With a 5/8 in. wrench remove the ori ce retaining nut.
Replace with the appropriate ori ce (.063 LP / .106 NG).
Remove the pilot hood and set aside.
Figure 6.4
Using a 5/32 in. (4 mm) Allen wrench, remove the pilot
injector and replace with an appropriate injector (#35 LP
/ #62 NG).
Reinstall burner and secure with the two screws previ-
ously removed.