40
Firebox
Repack
Insulation
Knockout
Combustible
Materials
Maintain air clearance
to combustibles.
Gas Line
Combustible materials
may be located at zero
clearance to gas line
beyond 4 in. (102 mm)
from fireplace side.
Gas Line
1-1/2 in.
(38 mm)
air space
Refractory
Seal with
fireplace mortar
or high temp
noncombustible
sealant
4 in.
(102 mm)
Outer Shell
of Fireplace
Figure 12.1 Gas Line Installation
12
12
Accessories
A. Gas Log/Lighter Provision
WARNING! Fire and/or Asphyxiation Risk! Use with
solid wood fuel or decorative gas appliance only. Gas fi re
generates fumes.
• DO NOT install unvented gas logs
• Damper must be locked fully open when gas logs are
installed
A certifi ed gas log lighter or decorative gas log set can be
installed in this fi replace.
• Maximum input is 100,000 BTU/hr.
• Decorative gas appliance must be certifi ed to ANSI
Z21.60 “Standard for Decorative Gas Appliances for
Installation in Vented Fireplaces”.
• Must be installed in accordance with the National Fuel
Gas Code, ANSI Z223.1.
• A gas log set must incorporate a gas shutoff.
• Gas log set requires the damper to be locked fully
open.
• A listed automatic damper system with safety interlock
may be used in this fi replace with only compatible,
listed gas log sets. See damper system manufacturer’s
instructions.
• Knockouts are provided on both sides of the fi replace
and in refractories for 1/2 in. (13 mm) iron pipe.
• Seal refractory around pipe with fi replace mortar or a
high temperature, noncombustible sealant.
B. Wood Burning Inserts
WARNING! Risk of Fire! Improper installation of wood in-
serts may cause fi replace or chimney system to overheat.
If a wood burning insert is being installed in this fi replace,
Hearth & Home Technologies recommends full reline of
the chimney.
• Cooling air openings at the top of the chimney must not
be obstructed in any manner.
• Hearth & Home Technologies recommends securing the
reline at the top of the fl ue and using the cap certifi ed for
use with this fi replace system.
C. Install Fan
• Optional.
• Follow instructions included with fan kit.
WARNING! Risk of Electric Shock! DO NOT remove
grounding prong from plug or route cord under or in
front of appliance. Plug directly into a properly ground-
ed three-prong receptacle and route cord away from
appliance.
Heatilator • A36C & A42C • 28396 • Rev AG • 11/08