Hearth and Home Technologies A36C Indoor Fireplace User Manual


 
30
Slanted Roofs
Flat Roofs
Chimney must
extend 3 ft (.9 m)
above the roof
Chimney must extend 2 ft (.6 m)
above any portion of the roof or
adjacent structures within
10 ft (3 m) of the chimney
Chimney must
extend 3 ft (.9 m)
above the roof
Chimney must extend 2 ft (.6 m)
above any portion of the roof or
adjacent structures within
10 ft (3 m) of the chimney
Multiple Chimney Locations
AB
6in.(minimum)upto20in.
152 mm/508 mm
18 in. minimum
457 mm
20 in. and over 0 in. minimum
Gas, Wood or Fuel Oil
Termination Cap
Wood
Minimum
(See
illustration
above)
B
Gas
Termination
Cap **
A *
Perpendicular Wall
*
Ifusingdecorativecapcover(s),thisdistancemayneedtobe
increased. Refer to the installation instructions supplied with the
decorative cap cover.
**
In a staggered installation with bothgas and wood terminations, the
wood termination capmust be higher than the gas terminationcap.
Figure 8.10 Multiple Chimney Locations
J. Chimney Termination Requirements
Install a cap approved and listed for this replace system.
Locate cap where it will not become plugged by snow or other materials.
Locate cap away from trees or other structures.
The bottom of the termination cap must be at least 3 ft (.91 m) above the roof AND at least 2 ft (.61 m) above any portion
of roof within 10 ft (3.05 m) as shown in Figure 8.10.
The distance required between caps is shown in Figure 8.10.
Heatilator • A36C & A42C • 28396 • Rev AG • 11/08
Î