Hearth and Home Technologies 823-0170 Indoor Fireplace User Manual


 
Page 17
Isle Royale Wood Stove
R
September 1, 2008
250-5763C
OUTSIDE AIR
TERMINATION CAP
(contains rodent screen)
FLEX FLANGE
1. Remove all materials from packing box.
2. Mount the ex ange (with pipe tting extending out),
over the intake air opening at the rear of stove using the
four mounting screws supplied with kit.
3. Cut a 4 inch (102mm) minimum hole in the oor or wall
to accommodate outside air piping. Use 4 inch (102mm)
metal ex or rigid piping to directly connect outside air to
the unit or into vented crawl space. (Do not put ex into
a non-vented crawl space). If using ex tubing attach
cable ties to secure tubing at both ends. Use the supplied
termination cap with a rodent screen. Seal between the
oor or wall and the pipe with silicone to prevent moisture
penetration.
Items Needed for Installation: 4 inch (102mm) diameter
ex pipe in the length as required for your installation;
Phillips screwdriver; Silicone sealant; Drills and saws
necessary for cutting holes through the wall or ooring
in your home.
Included in Kit: 1 ex ange; 2 cable ties; oustide air
termination cap; mounting screws (Discard the remaining
parts).
OUTSIDE AIR KIT INSTALLATION
NOTE: If you plan to install the optional blower and the
outside air kit, complete installation of the outside
air kit rst.
1. Remove 3 Phillips head screws from rear of unit.
2. Using the Phillips head screws, attach blower to lower rear
of stove, as shown.
3. Plug blower cord into a grounded outlet. Do not remove
ground prong from plug. Route power cord to avoid heat
from the stove, or other damage. Do not route cord under
or in front of appliance.
4. Adjust the blower speed control to the desired speed.
INSTALLATION OF OPTIONAL BLOWER
The blower is shipped fully assembled and ready for installation.
ADJUSTING THE BLOWER SPEED CONTROL,*
If Necessary
NOTE: When the speed control is turned clockwise, it will click on
to high speed. Turn the speed control clockwise to decrease
the speed. At full clockwise, the blower should blow gently,
but should not stop.
1. With the unit plugged in, turn the speed control knob to slow
(full clockwise).
2. With a small screwdriver, adjust the blower speed by turning
the adjustment mechanism through the hole on the side of
the speed control.
3. Adjust the speed so the blower runs slowly, but does not stop.
Turn clockwise to slow the blower and counterclockwise to
increase the speed.
*The blower speed control for this unit is adjusted at the factory,
and normally does not require further adjustment.
Rear Shield
Blower Mounting
Flange
Blower Speed Control
Blower
Mounting
Flange
Rear
Shield