Hearth and Home Technologies 42-B Indoor Fireplace User Manual


 
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09 7
B
A
G
E
Note: If this surface is
inside the building’s
warm air envelope...
...then this surface
must be an exterior
wall system.
C
D
F
F
C
D
G
F
E
57-3/4 in.
(1467 mm)
81-3/4 in.
(2076 mm)
Note:
Illustrations reect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
Fire Risk
Provide adequate clearance:
Around air openings.
To combustibles.
For service access.
Locate appliance away from trafc areas.
WARNING
A. Select Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (See Figure 3.1).
Note: For actual appliance
dimensions refer to Section 13.
Figure 3.1 Appliance Locations
3
Framing and Clearances
A B C D E F G
in. 24-3/4 24-1/8 48 49 5/8 1/2 1-1/2
mm 629 613 1219 1245 16 13 38
Fire Risk
Odor Risk
Install appliance on hard metal or wood
surfaces extending full width and depth
of appliance.
Do NOT install appliance directly on
carpeting, vinyl, tile or any combustible
material other than wood.
WARNING
Fire Risk
Locate and install appliance to all
clearance specications in manual.
WARNING