E. Valve Access
Washer
Figure 6.1 Lift Out Doors
Figure 6.3 Loosen Refractory Retaining Strip
Figure 6.4 Remove Valve Access Panel
Figure 6.5 Remove Exterior Valve Access Panel
Figure 6.6 Connect Manometer
The gas valve can be accessed behind the cement
refractory panel on the right side of the replace.
Lift doors out and set aside. There is a washer under each
door. Be careful not to loose those washers.
Use a phillips screwdriver to remove the exterior valve
access panel (remove four screws).
Use a manometer on the lower out pressure tap. Start
up the replace to verify the pressure and adjust as
necessary. Reverse these steps to reassemble before log
positioning.
Remove logs if access is necessary after installation is
complete. See Section 9.C. Remove logs in reverse order
of set up.
Remove grate if access is necessary after installation is
complete. (Refer to Section 9.B.)
Remove two screws on side of pilot shield and remove
shield.
Remove the inside valve access panel by lifting it up and
out.
Figure 6.2 Remove Pilot Shield
Use a phillips screwdriver to remove the two screws
securing the refractory retaining strip. Remove the
refractory side panel and set aside.