Hearth and Home Technologies 42-B Indoor Fireplace User Manual


 
14 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B • 4036-909 • Rev L 10/09
Battery polarity must be correct or module damage will
occur.
CAUTION
A. Intellire Ignition System Wiring
This appliance is equipped with an Intellire control valve
which operates on a 3 volt system.
This appliance is supplied with a battery pack which is
located in the ON/OFF switch terminal box. A wiring
diagram is shown in Figure 7.1.
The battery pack requires two D cell batteries (not
included). See Section 12.B. for battery replacement.
7
Electrical Information
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
CAUTION
Shock Risk
Replace damaged wire with type 105° C
rated wire.
Wire must have high temperature
insulation.
WARNING
IGNITION MODULE
3 VAC
GRN
ORG
INTERMITTENT
PILOT
IGNITOR
IGNITION
MODULE
(3V)
ON/OFF
WALL
SWITCH
LOW VOLTAGE
BATTERY
PACK
FLAME SPARKER/
SENSOR
SEE NOTE 1
ORG
WHT
PIGGYBACK
ON/OFF SWITCH
BRN
BRN
VALVE
VALVE
GROUND TO
FIREPLACE
CHASSIS
I
S
BLACK
RED
BATTERY
PACK
Figure 7.1 Intellere Pilot Ignition (IPI) Wiring Diagram