Harman Stove Company R16 Electric Heater User Manual


 
12
XXV Pellet Stove

This method provides excellent venting for normal
operation. This method also provides natural draft in
the event of a power failure. If the chimney condition
is questionable* you may want to install a liner as in
method #6.
*The chimney should be inspected and cleaned
before installing your stove. If you discover that the
chimney does not have a clay tile liner or has cracks or
aking of the tile liner you will need to install a stainless
steel liner within the chimney. In most cases the inside
diameter of this liner should be 4". Either exible or rigid
liner may be used for this purpose. Refer to Method 6.
Be sure to design the venting so that it can be easily
cleaned.

     
     

This method will allow single wall 6" ue pipe to come
off the top of the stove and go directly into a masonry
or class A chimney.
This method will be desirable for people who are
replacing a wood or coal stove and have an existing
chimney to use.
Fig. 13
 from
pipe to wall
Fig. 12
 

      




