Harman Stove Company R16 Electric Heater User Manual


 
11
XXV Pellet Stove

This method provides excellent venting for normal
operation and allows the stove to be installed closest to
the wall. Two inches from the wall is safe; however, four
inches allows better access to remove the rear panel.
The vertical portion of the vent should be three to ve
feet high. This vertical section will help provide natural
draft in the event of a power failure. 







This method also provides excellent venting for
normal operation but requires the stove to be installed
farther from the wall. The vertical portion of the vent
should be three to ve feet high and at least three
inches from a combustible wall. This vertical section
will provide natural draft in the event of a power failure.
If the stove is installed below grade be sure the vent
termination is at least 18" above grade. The outlet must
also be 1 foot from the house/building.
Note: Do not place joints within wall pass-
throughs
Fig. 9

to
Combustibles

to Combustibles
Fig. 10

to
Combustibles

to Combustibles
Fig. 11
12" min. wall to outlet
Shaded area represents
the minimum clearance to
combustible materials such as
shrubbery, mulch or tall grasses.



