Harman Stove Company 2 Stove User Manual


 
17
Min. above ground level
18"
Minimum flue vent configuration
It is recommended that
outside air be installed with this
venting configuration to reduce
smoke and creosote smell in the
room in the event of power failure.
#8 Installing through the ceiling vent
Through the ceiling vent, follow PLvent
manufacturers recommendations when using wall
and ceiling pass through. Note: Do not place joints
within wall pass-throughs.
PL vent manufacturer's
firestop spacer and
support
No insulation or
other combustible
materials are
allowed within 3"
of the PL vent
pipe.
Storm collar
Flashing
3" min.
3" min.
3" min.
12" min.
(See Page 9 for
corner installation
clearances)
Fig. 31
Fig. 32
Fig. 33
Venting
Shaded area represents the
minimum clearance to combustible
materials such as shrubery,
mulch or tall grasses.
36"
36" min clearance to any
combustible material
12" min. wall to outlet