Hans Grohe 26310001 Plumbing Product User Manual


 
7
Justify the Handle:
Turn the handshower on.
Turn the temperature control handle until the output water
measures 100
o
on a thermometer.
Turn the handshower off. Do not move the tempera-
ture control handle.
Without turning it, remove the temperature control handle.
Remove the safety set. Reinstall it so that it is oriented as
shown in the diagram.
Reinstall the handle so that the safety stop override button is
at the 12:00 position. Install and tighten the handle screw.
Loosen the handle screw 1/4 - 1/2 turn. Install the screw
cover.
safety set