Installation procedure
Install indoor unit
Notice
Do not install the air conditioner at the place where
the combustible gas maybe leak. In case of the leaked
gas gather around the unit, it may cause fire accident.
The indoor unit should be installed in the place where the cool air and warm air may
evenly circulate.
Avoid the following places:
Place with too much salinity (coastal area).
Place with too much sulfuration gas (mainly is the hotspring area,
the copper pipe and brazed part are easily corroded).
Place with too much oil (including mechanical oil) and vapor.
Place using organic solvent.
Place with machines may generate high frequency electromagnetic waves.
(The control system may have abnormality)
Place near the doors or windows that come close to the external high humidity
air. (may easily form dew)
Place where the special sprayer may be frequently used.
On vehicles, boats and ships.
Place less than 1m away from TV, radio, radio devices and fluorescent lamp.
Indoor unit
1. Choose the place where the air from the air conditioner can spread
throughout the room and where the connection pipe, connection wire
and drain hose may be easily arranged to the suitable outdoor position.
2. Choose the place where the vertical distance between the center of air
outlet and the ground is no more than 2.7m.
3. The structure of the ceiling should be firm enough to bear the weight of the unit.
4. The connection pipe, drain hose and connection wire can penetrate
through the wall and connect indoor and outdoor unit.
5. The connection pipe and drain hose between indoor and outdoor unit
should be as short as possible.
6. The connection flare should be provided by user.
Safety precautions
1. For those models with electric heat function, it is forbidden to directly
connect the air outlet with canvas and material alike inflammable interfaces.
2. When installing indoor unit, it is necessary to leave a checking hole for
convenient repair.