Haier AC242ACEAA Air Conditioner User Manual


 
Installation Procedures
HOW TO CONNECT WIRING TO THE TERMINALS
A. For solid core wiring (or F-cable)(Fig.24A)
(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 25mm of the
exposed solid wire.
(2) Using a screwdriver, remove the terminal screw(s) on the terminal board.
(3) Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
(4) Shape the loop wire properly, place it on the terminal board and tighten securely with the terminal
screw using a screw driver.
B. For strand wiring(Fig.24B)
(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 10mm of the
exposed strand wiring.
(2) Using a screwdriver, remove the terminal screw(s)on the terminal board.
(3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end.
(4) Position the round terminal wire, and replace and tighten the terminal screw using a screw driver.
Fig. 24
Insulation
Strip 25mm
Loop
A. Solid wire
Terminal
board
Screw with
special washer
Round
terminal
Wire
Screw with
special washer
Round
terminal
Wire
Strip 10mm
Round
terminal
B. Strand wire
After passing the connection cord and power cable through the insulation tube, fasten it with the cord
clamp, as shown in Fig.25
HOW TO FIXED CONNECTION CORD AND POWER CABLE AT
THE CORD CLAMP
Fig. 25
Insulation tube
Cord clamp
Use VW-1, 0.5 to 1.0 mm thick, PVC tube as the insulation tube.
13