Service
20 310622L
For Sanitary Ball Check pumps: remove ball gasket
(242) and ball (541). Remove lower clamp (132b),
seat (233), and gasket (240). Clean all parts and
inspect for wear or damage. Replace parts as
needed.
For Flapper Check pumps: remove gasket (240).
Remove middle clamp (232) and housing (252).
Remove middle gasket (250), flapper retainer (253),
and flapper valve (251). Remove lower clamp
(132b), lower flapper housing (248), and gasket
(240). Clean all parts and inspect for wear or dam-
age. Replace parts as needed.
6. Disassemble the outlet manifold. Remove clamps
(130), tee (339), gasket (129), and elbow (128).
Clean all parts and inspect for wear or damage.
Replace parts as needed.