Graco TI15596a Septic System User Manual


 
Performance Charts
28 3A0538F
NOTE: See Models on page 3 for your pump part number.
NXT 3400 Air Motor, 1500cc Lower (JX45XX)
FLUID PRESSURE
FLUID FLOW IN GPM (LPM)
AIR FLOW
psi (MPa, bar)
500 (3.5, 35)
400 (2.8, 28)
300 (2.1, 21)
200 (1.4, 14)
100 (0.7, 7)
0
2.0
(7.0)
4.0
(15.0)
6.0
(22.5)
8.0
(30.0)
10.0
(37.9)
12.0
(45.4)
14.0
(53.0)
0
80 (2.24)
60 (1.68)
40 (1.12)
20 (0.56)
SCFM (m
3
/min.)
0 (0.0)
B
A
C
B
A
C
70 (1.96)
50 (1.4)
30 (0.84)
10 (0.28)
450 (3.1, 31)
350 (2.4, 24)
250 (1.7, 17)
150 (1.0, 10)
50 (0.3, 3)
NXT 3400 Air Motor, 2000cc Lower (JX35XX)
FLUID PRESSURE
FLUID FLOW IN GPM (LPM)
AIR FLOW
psi (MPa, bar)
300 (2.1, 21)
200 (1.4, 14)
100 (0.7, 7)
0
2.0
(7.0)
4.0
(15.0)
6.0
(22.5)
8.0
(30.0)
10.0
(37.9)
12.0
(45.4)
14.0
(53.0)
0
60 (1.68)
40 (1.12)
20 (0.56)
0
B
A
C
B
A
C
50 (1.4)
30 (0.84)
10 (0.28)
350 (2.4, 24)
250 (1.7, 17)
150 (1.0, 10)
50 (0.3, 3)
SCFM (m
3
/min.)
0
4
8
11
14
17
21 24
NXT 3400 Air Motor, 3000cc Lower (JX23XX)
FLUID PRESSURE
FLUID FLOW IN GPM (LPM)
AIR FLOW
psi (MPa, bar)
0
5.0
(19)
20.0
(76)
25.0
(95)
30.0
(114)
10.0
(38)
15.0
(57)
0
80 (2.24)
60 (1.68)
40 (1.12)
20 (0.56)
0
B
CYCLES PER MIN.
A
C
B
A
C
70 (1.96)
50 (1.4)
30 (0.84)
10 (0.28)
NXT 3400 Air Motor, 4000cc Lower (JX17XX)
FLUID PRESSURE
AIR FLOW
psi (MPa, bar)
70 (1.96)
B
CYCLES PER MIN.
A
C
B
A
C
50 (1.4)
30 (0.84)
10 (0.28)
0 6 13 19 25 32 38
250
(1.7, 17)
200
(1.4, 14)
150
(1.0, 10)
100
(0.7, 7)
50
(0.3, 3)
05 9 14 19
24
28
CYCLES PER MIN.
0
5
10
15
20
24
28
32
FLUID FLOW IN GPM (LPM)
0
5.0
(19)
20.0
(76)
25.0
(95)
30.0
(114)
10.0
(38)
15.0
(57)
0
0
CYCLES PER MIN.
180
(1.2, 12)
120
(0.8, 8)
60
(0.4, 4)
SCFM
(m
3
/min.)
SCFM
(m
3
/min.)
Key:
A 100 psi (0.7 MPa, 7.0 bar) air pressure
B 70 psi (0.49 MPa, 4.9 bar) air pressure
C 40 psi (0.28 MPa, 2.8 bar) air pressure
NOTE: The shaded area within the table shows the recom-