Graco 3A0019J Water Pump User Manual


 
Parts
14 3A0019J
Parts
5cc, 10cc, and 15cc Pumps
1. Lubricate seals, o-rings, lead-in’s and moving parts with
grease.
Apply one stripe of removable strength anaerobic sealant on
threads.
Torque to 50-ft-lbs (67.5 N•m).
Assemble and torque after displacement rod (15) is assembled
through throat retainer (19). See table on page 13 for torque
specification.
Torque evenly to 50-200 ft-lbs (60-270 N•m), all to the same
torque value.
Fully tighten with a wrench.
See table on page 11 for torque specification.
Must be pressed straight into housing.
Apply anti-seize lubricant to threads.
Ensure u-cup (26) springs face throat cartridge (18).
Ensure u-cup (17) springs face displacement rod (15).
Fully assemble seal (17) and bearing (16) onto displacement
rod (15) before tightening piston retainer (14).
NOTICE
Specification sheets and Graco testing indicate that anaer-
obic sealant requires three days to fully cure. Failure to
allow three days for full cure may result in parts coming
loose during operation.
If faster cure time is needed,
Rapid Sealant Cure Kit is available, 24N985.