Graco 308791E Thermostat User Manual


 
308791 5
Operation
Optional Gun Air Regulator 235119
NOTE:
D Installing the gun air inlet regulator adds a pressure
drop that could limit the air cap pressure.
D See Accessories on page 11 for air regulator
replacement parts.
1. Pull up the gun regulator adjustment knob lock-ring
(L); this allows the knob to turn. See Fig. 5.
2. Set the gun air pressure at zero by turning the
regulator adjustment knob (K) fully counterclock-
wise.
3. Turn on the air supply to the gun.
4. Turn the regulator adjustment knob (K) clockwise
to increase the air pressure to the gun.
WARNING
Never exceed 100 psi (7 bar) Maximum Working
Air Pressure to the gun. Exceeding the maxi-
mum working pressure of the gun or any other
system component could cause component
rupture, which could result in serious injury and
property damage.
5. Push the adjustment knob lock-ring (L) down to
hold the pressure setting.
Fig. 5
L
K
7614A