Graco 223596 Septic System User Manual


 
307619 23
Technical Data
0
1000
2000
3000
4000
5000
0.0 0.2 0.4 0.6 0.8
President 46:1 Fluid Outlet Pressure
21 41 8262
psi
MPa, bar
cycles per minute
gpm
liters/minute
0.8 2.31.5 3.0
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
FLUID PRESSURE
21, 210
7,70
A
B
C
To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
A 100 psi (0.7 MPa, 7 bar) air pressure
B 70 psi (0.49 MPa, 4.9 bar) air pressure
C 40 psi (0.28 MPa, 2.8 bar) air pressure
0
10
20
30
40
0.0 0.2 0.4 0.6 0.8
President 46:1 Air Consumption
21
41
8262
scfm
m#/min
cycles per minute
gpm
liters/minute
0.8 2.31.5 3.0
FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)
AIR CONSUMPTION
A
B
C
1.12
0.84
0.56
0.28
14, 140
35, 350
Models 239140 46:1 Ratio SST President Performance Chart
28, 280