Installation
General Information
D The Typical Installation shown in Fig. 2 is only a
guide for selecting and installing system compo-
nents. Contact your Graco distributor for assistance
in planning a system to suit your needs.
D Always use Genuine Graco Parts and Accessories.
D Reference numbers and letters in parentheses refer
to the callouts in the figures and the parts lists on
pages 12–34.
D For ETL listed pumps. All pipe joints are to be
made tight with ETL listed gasoline–resistant pipe
compound.
Grounding the System
WARNING
FIRE AND EXPLOSION HAZARD
This pump must be grounded. Before
operating the pump, ground the system
as explained below. Also read the sec-
tion FIRE AND EXPLOSION HAZARD
on page 3.
To reduce the risk of static sparking, ground the pump
and all other equipment used or located in the pumping
area. Check your local electrical code for detailed
grounding instructions for your area and type of equip-
ment. Ground all of this equipment.
1. ETL–Listed Pumps: Use a ground wire, connector,
and clamp. See Fig. 1. Loosen screw (X). Insert
one exposed end of a 12 ga (1.5 mm
2
) minimum
ground wire (Y) through the eye of the ground
terminal connector (W) and tighten screw (X)
securely. Connect the other end of the wire to a
true earth ground. Order Part No. 237569 Ground
Wire and Clamp.
2. Non ETL–Listed Pumps: See Fig. 1. Remove the
ground screw (Z). Fasten the ground connector
(W) onto the pump with the ground screw (Z) and
tighten securely. Loosen screw (X). Insert one
exposed end of a 12 ga (1.5 mm
2
) minimum
ground wire (Y) through the eye of the ground
terminal connector (W) and tighten screw (X)
securely. Connect the other end of the wire to a
true earth ground. Order Part No. 222011 Ground
Connector/Wire and Clamp.
Fig. 1
TI1052
Y
Z
X
W
3. Air and fluid hoses: use only electrically conductive
hoses.
4. Air compressor: according to manufacturer’s
recommendations.
5. Dispensing valve: grounding is obtained through
connection to a properly grounded fluid hose and
pump.
6. Fluid supply container: according to local code.
7. Object being sprayed: according to local code.
8. All solvent pails used when flushing, according to
local code. Use only metal pails, which are con-
ductive. Do not place the pail on a non-conductive
surface, such as paper or cardboard, which inter-
rupts the grounding continuity.