Goodman Mfg RT6621031r2 Furnace User Manual


 
7
PRODUCT DIMENSIONS
GMS8[040-100]BB
GMS81205D*BA
GMS81405DNCC
For installations in Canada, the GMS furnaces are certifed only to 4,500 ft.
* Negative pressure readings are in inches of water column (*w.c.)
Model
Trip Point
ID Blower
Pressure
Switch
ID Blower
Pressure
Switch
Part #
GMS80403A*BB
-0.70 B1370158
GMS80603A*BB
-0.75 B1370179
GMS80604B*BB
-0.75 B1370179
GMS80804B*BB
-0.70 B1370158
GMS80805C*BB
-0.75 B1370179
GMS81005C*BB
-0.70 B1370158
GMS81205D*BA
-0.80 0130F00042
GMS81405DNCC
-0.80 0130F00042
Pressure Switch Trip Points
Part Number 20162901 20162904 20162903
Open Setting (°F) 210 150 160
GMS80403A*BB 1 --- ---
GMS80603A*BB --- 1 ---
GMS80604B*BB --- 1 ---
GMS80804B*BB --- 1 ---
GMS80805C*BB --- --- 1
GMS81005C*BB --- 1 ---
GMS81205D*BA --- --- 1
GMS81405DNCC --- --- 1
PRIMARY LIMIT
Part Number 10123529
Open Setting (°F) 300
GMS80403A*BB 2
GMS80603A*BB 2
GMS80604B*BB 2
GMS80804B*BB 2
GMS80805C*BB 2
GMS81005C*BB 2
GMS81205D*BA 2
GMS81405DNCC 2
ROLLOUT LIMIT SWITCHES
Part Number 0130F00038
Open Setting (°F) 120
GMS80403A*BB 1
GMS80603A*BB 1
GMS80604B*BB 1
GMS80804B*BB 1
GMS80805C*BB 1
GMS81005C*BB 1
GMS81205D*BA 1
GMS81405DNCC 1
AUXILIARY LIMIT SWITCHES