Goodman Mfg RS6300011 Air Conditioner User Manual


 
34
COOLING PERFORMANCE DATA
GPC1430H41AB
5MM COILS
MODEL: GPC1430H41A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 27.8 28.8 31.6 - 27.2 28.2 30.9 - 26.5 27.5 30.1 - 25.9 26.8 29.4 - 24.6 25.5 27.9 - 22.8 23.6 25.9 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
Delta T171411 - 171511 - 171511 - 17 15 11 - 171411 - 161310 -
1145 KW 1.75 1.78 1.84 - 1.89 1.93 1.99 - 2.01 2.05 2.12 - 2.12 2.16 2.24 - 2.21 2.26 2.34 - 2.29 2.34 2.42 -
AMPS 7.9 8.1 8.3 - 8.5 8.6 8.9 - 9.1 9.3 9.5 - 9.6 9.8 10.1 - 10.2 10.4 10.7 - 10.7 10.9 11.3 -
HI PR 234 252 266 - 263 283 299 - 299 322 340 - 341 367 387 - 383 412 435 - 423 456 481 -
LO PR 108 115 125 - 114 121 132 - 118 126 138 - 124 132 145 - 130 139 151 - 135 143 157 -
MBh 27.0 28.0 30.7 - 26.4 27.4 30.0 - 25.8 26.7 29.3 - 25.1 26.1 28.5 - 23.9 24.7 27.1 - 22.1 22.9 25.1 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.80 0.67 0.47 - 0.81 0.68 0.47 -
Delta T171511 - 171511 - 171511 - 18 15 12 - 171511 - 161411 -
70 1020 KW 1.73 1.77 1.83 - 1.87 1.91 1.97 - 1.99 2.04 2.10 - 2.10 2.15 2.22 - 2.19 2.24 2.32 - 2.27 2.32 2.40 -
AMPS 7.9 8.0 8.2 - 8.4 8.6 8.8 - 9.0 9.2 9.5 - 9.5 9.8 10.0 - 10.1 10.3 10.6 - 10.6 10.8 11.2 -
HI PR 232 250 264 - 260 280 296 - 296 319 336 - 337 363 383 - 379 408 431 - 419 451 476 -
LO PR 107 114 124 - 113 120 131 - 117 125 136 - 123 131 143 - 129 137 150 - 134 142 155 -
MBh 25.7 26.6 29.1 - 25.1 26.0 28.5 - 24.5 25.4 27.8 - 23.9 24.7 27.1 - 22.7 23.5 25.8 - 21.0 21.8 23.9 -
S/T 0.68 0.57 0.39 - 0.70 0.59 0.41 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.78 0.65 0.45 -
Delta T181512 - 181612 - 181612 - 18 16 12 - 181512 - 171411 -
900 KW 1.70 1.74 1.80 - 1.84 1.88 1.94 - 1.96 2.00 2.07 - 2.06 2.11 2.18 - 2.15 2.20 2.28 - 2.23 2.28 2.36 -
AMPS 7.7 7.9 8.1 - 8.3 8.4 8.7 - 8.9 9.1 9.3 - 9.4 9.6 9.9 - 9.9 10.1 10.4 - 10.4 10.7 11.0 -
HI PR 227 245 258 - 255 275 290 - 290 312 330 - 330 356 376 - 372 400 422 - 411 442 467 -
LO PR 105 111 122 - 111 118 128 - 115 122 133 - 121 128 140 - 127 135 147 - 131 139 152 -
MBh 28.3 29.1 31.5 33.9 27.6 28.5 30.8 33.1 27.0 27.8 30.1 32.3 26.3
27.1
29.3 31.5 25.0 25.8 27.9 29.9 23.2 23.9 25.8 27.7
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.92
0.83
0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.65 0.42
Delta T19181410191815101918151020
18
15 10 19 18 15 10 18 17 14 9
1145 KW 1.76 1.80 1.86 1.92 1.90 1.94 2.01 2.08 2.03 2.07 2.14 2.21 2.14
2.18
2.26 2.34 2.23 2.28 2.36 2.44 2.31 2.36 2.44 2.53
AMPS 8.08.18.48.68.58.79.09.29.29.49.69.99.7
9.9
10.2 10.5 10.2 10.5 10.8 11.1 10.8 11.0 11.3 11.7
HI PR 237 255 269 281 266 286 302 315 302 325 343 358 344
370
391 408 387 417 440 459 428 460 486 507
LO PR 109 116 127 135 115 122 134 142 120 127 139 148 126
134
146 155 132 140 153 163 136 145 158 169
MBh 27.5 28.3 30.6 32.9 26.8 27.6 29.9 32.1 26.2 27.0 29.2 31.3 25.6
26.3
28.5 30.6 24.3 25.0 27.1 29.0 22.5 23.2 25.1 26.9
S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88
0.79
0.60 0.38 0.91 0.82 0.62 0.40 0.92 0.83 0.62 0.40
Delta T20181510201915102019151120
19
15 11 20 18 15 10 19 17 14 10
75 1020 KW 1.75 1.79 1.84 1.90 1.89 1.93 1.99 2.06 2.01 2.05 2.12 2.20 2.12
2.17
2.24 2.32 2.21 2.26 2.34 2.42 2.29 2.34 2.42 2.51
AMPS 7.98.18.38.68.58.68.99.29.19.39.59.99.6
9.8
10.1 10.5 10.2 10.4 10.7 11.0 10.7 10.9 11.3 11.6
HI PR 234 252 266 278 263 283 299 312 299 322 340 354 341
367
387 404 383 412 435 454 423 456 481 502
LO PR 108 115 125 133 114 121 132 141 118 126 138 147 124
132
145 154 130 139 151 161 135 144 157 167
MBh 26.1 26.9 29.1 31.2 25.5 26.3 28.4 30.5 24.9 25.6 27.7 29.8 24.3
25.0
27.1 29.0 23.1 23.8 25.7 27.6 21.4 22.0 23.8 25.6
S/T 0.77 0.69 0.52 0.34 0.80 0.71 0.54 0.35 0.82 0.73 0.55 0.36 0.84
0.76
0.57 0.37 0.88 0.78 0.59 0.38 0.88 0.79 0.60 0.38
Delta T21191511211916112119161121
19
16 11 21 19 16 11 19 18 15 10
900 KW 1.72 1.76 1.81 1.87 1.85 1.90 1.96 2.02 1.97 2.02 2.09 2.16 2.08
2.13
2.20 2.28 2.17 2.22 2.30 2.38 2.25 2.30 2.38 2.46
AMPS 7.88.08.28.48.38.58.79.08.99.19.49.79.5
9.7
10.0 10.3 10.0 10.2 10.5 10.9 10.5 10.7 11.1 11.4
HI PR 230 247 261 272 258 277 293 305 293 315 333 347 334
359
379 396 376 404 427 445 415 447 472 492
LO PR 106 112 123 131 112 119 130 138 116 124 135 144 122
130
142 151 128 136 148 158 132 141 154 164
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.