Goodman Mfg RS6300011 Air Conditioner User Manual


 
14
COOLING PERFORMANCE DATA GPC1424H41AA
MODEL: GPC1424H41A*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 9 ± 2°F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 5 ± 2°F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 24.1 25.0 27.4 - 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5 - 21.3 22.1 24.2 - 19.7 20.5 22.4 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.85 0.71 0.49 -
Delta T171511 - 171511 - 171511 - 18 15 12 - 171511 - 161411 -
955 KW 1.57 1.60 1.66 - 1.70 1.73 1.79 - 1.81 1.85 1.91 - 1.91 1.95 2.02 - 1.99 2.04 2.11 - 2.06 2.11 2.19 -
AMPS 6.6 6.8 7.0 - 7.1 7.3 7.5 - 7.7 7.9 8.1 - 8.2 8.4 8.7 - 8.7 8.9 9.2 - 9.2 9.4 9.7 -
HI PR 233 251 265 - 262 282 298 - 298 321 338 - 339 365 386 - 382 411 434 - 422 454 479 -
LO PR 111 118 129 - 118 125 137 - 122 130 142 - 128 137 149 - 135 143 156 - 139 148 162 -
MBh 23.4 24.3 26.6 - 22.9 23.7 26.0 - 22.3 23.1 25.3 - 21.8 22.6 24.7 - 20.7 21.4 23.5 - 19.2 19.9 21.8 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 -
Delta T181612 - 181612 - 181612 - 18 16 12 - 181612 - 171511 -
70 850 KW 1.56 1.59 1.64 - 1.68 1.72 1.78 - 1.79 1.83 1.90 - 1.89 1.93 2.00 - 1.97 2.02 2.09 - 2.05 2.09 2.17 -
AMPS 6.6 6.7 6.9 - 7.1 7.2 7.5 - 7.7 7.8 8.1 - 8.1 8.3 8.6 - 8.6 8.8 9.1 - 9.1 9.3 9.6 -
HI PR 231 249 263 - 259 279 295 - 295 317 335 - 336 361 382 - 378 407 429 - 418 449 474 -
LO PR 110 117 128 - 116 124 135 - 121 129 141 - 127 135 148 - 133 142 155 - 138 147 160 -
MBh 21.6 22.4 24.5 - 21.1 21.9 24.0 - 20.6 21.3 23.4 - 20.1 20.8 22.8 - 19.1 19.8 21.7 - 17.7 18.3 20.1 -
S/T 0.68 0.57 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.78 0.66 0.45 -
Delta T181612 - 181612 - 181612 - 19 16 12 - 181612 - 171511 -
745 KW 1.52 1.55 1.60 - 1.64 1.68 1.73 - 1.75 1.79 1.85 - 1.84 1.88 1.95 - 1.92 1.97 2.03 - 1.99 2.04 2.11 -
AMPS 6.4 6.6 6.8 - 6.9 7.1 7.3 - 7.5 7.6 7.9 - 7.9 8.1 8.4 - 8.4 8.6 8.9 - 8.9 9.1 9.4 -
HI PR 224 241 255 - 252 271 286 - 286 308 325 - 326 351 370 - 367 394 417 - 405 436 460 -
LO PR 107 114 124 - 113 120 131 - 117 125 136 - 123 131 143 - 129 137 150 - 134 142 155 -
MBh 24.5 25.2 27.3 29.3 23.9 24.7 26.7 28.6 23.4 24.1 26.0 28.0 22.8
23.5
25.4 27.3 21.7 22.3 24.1 25.9 20.1 20.7 22.4 24.0
S/T 0.84 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93
0.83
0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.66 0.42
Delta T20181510201915112019151120
19
15 11 20 18 15 10 19 17 14 10
955 KW 1.58 1.62 1.67 1.73 1.71 1.75 1.81 1.87 1.82 1.87 1.93 2.00 1.92
1.97
2.04 2.11 2.01 2.06 2.13 2.20 2.08 2.13 2.20 2.28
AMPS 6.76.87.17.37.27.47.67.97.88.08.28.58.3
8.5
8.7 9.1 8.8 9.0 9.3 9.6 9.3 9.5 9.8 10.2
HI PR 236 254 268 279 265 285 301 314 301 324 342 357 343
369
389 406 386 415 438 457 426 458 484 505
LO PR 112 120 131 139 119 126 138 147 123 131 143 153 130
138
151 160 136 145 158 168 141 150 163 174
MBh 23.8 24.5 26.5 28.5 23.2 23.9 25.9 27.8 22.7 23.4 25.3 27.1 22.1
22.8
24.7 26.5 21.0 21.7 23.4 25.2 19.5 20.1 21.7 23.3
S/T 0.81 0.72 0.55 0.35 0.83 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.88
0.79
0.60 0.38 0.92 0.82 0.62 0.40 0.92 0.83 0.63 0.40
Delta T21191611211916112119161121
19
16 11 21 19 16 11 19 18 15 10
75 850 KW 1.57 1.60 1.66 1.71 1.70 1.73 1.79 1.85 1.81 1.85 1.91 1.98 1.91
1.95
2.02 2.09 1.99 2.04 2.11 2.18 2.06 2.11 2.19 2.26
AMPS 6.66.87.07.27.17.37.57.87.77.98.18.48.2
8.4
8.7 9.0 8.7 8.9 9.2 9.5 9.2 9.4 9.7 10.1
HI PR 233 251 265 277 262 282 298 310 298 321 339 353 339
365
386 402 382 411 434 452 422 454 479 500
LO PR 111 118 129 138 118 125 137 145 122 130 142 151 128
137
149 159 135 143 156 166 139 148 162 172
MBh 22.0 22.6 24.5 26.3 21.5 22.1 23.9 25.7 20.9 21.6 23.3 25.1 20.4
21.0
22.8 24.4 19.4 20.0 21.6 23.2 18.0 18.5 20.0 21.5
S/T 0.78 0.69 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.85
0.76
0.58 0.37 0.88 0.79 0.60 0.39 0.89 0.80 0.60 0.39
Delta T21191611212016112120161121
20
16 11 21 20 16 11 20 18 15 10
745 KW 1.53 1.56 1.61 1.67 1.65 1.69 1.75 1.81 1.76 1.80 1.86 1.93 1.86
1.90
1.97 2.03 1.94 1.98 2.05 2.12 2.01 2.06 2.13 2.20
AMPS 6.56.66.87.17.07.17.37.67.57.77.98.28.0
8.2
8.4 8.7 8.5 8.7 9.0 9.3 9.0 9.2 9.5 9.8
HI PR 226 244 257 268 254 273 289 301 289 311 328 343 329
354
374 390 370 398 421 439 409 440 465 485
LO PR 108 115 125 134 114 121 133 141 119 126 138 147 125
133
145 154 131 139 152 161 135 144 157 167
* IDB: Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions
High and low pressures are measured at the liquid and suction access fittings.