Goodman Mfg GSX16 Air Conditioner User Manual


 
12 www.goodmanmfg.com SS-GSX16
SS-GSX16 www.goodmanmfg.com 13
Product SPecificationS
Product SPecificationS
EXpAndEd coolinG dAtA GSX160421f* / cA*f4860*6d*+tXV
Outdoor Ambient Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
70
1225
MBh 36.9 38.2 41.9 - 36.0 37.3 40.9 - 35.2 36.4 39.9 - 34.3 35.6 39.0 - 32.6 33.8 37.0 - 30.2 31.3 34.3 -
S/T 0.70 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.62 0.43 - 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.81 0.67 0.47 -
∆T 19 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 -
kW 2.70 2.76 2.83 - 2.89 2.95 3.03 - 3.06 3.12 3.21 - 3.20 3.27 3.37 - 3.33 3.39 3.50 - 3.43 3.50 3.61 -
Amps 9.9 10.1 10.4 - 10.7 10.9 11.3 - 11.6 11.8 12.2 - 12.3 12.6 13.1 - 13.1 13.4 13.9 - 13.9 14.2 14.7 -
Hi PR 220 237 250 - 247 265 280 - 281 302 319 - 320 344 363 - 359 387 409 - 397 427 451 -
Lo PR 102 109 119 - 108 115 125 - 112 119 130 - 118 125 137 - 124 131 143 - 128 136 148 -
1400
MBh 40.0 41.4 45.4 - 39.0 40.5 44.3 - 38.1 39.5 43.3 - 37.2 38.5 42.2 - 35.3 36.6 40.1 - 32.7 33.9 37.1 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.84 0.70 0.48 -
∆T 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 16 12 -
kW 2.76 2.82 2.90 - 2.96 3.02 3.10 - 3.13 3.19 3.29 - 3.28 3.34 3.45 - 3.40 3.48 3.58 - 3.51 3.59 3.70 -
Amps 10.1 10.4 10.7 - 10.9 11.2 11.6 - 11.9 12.2 12.6 - 12.7 13.0 13.4 - 13.5 13.8 14.3 - 14.3 14.6 15.1 -
Hi PR 227 244 258 - 254 274 289 - 289 311 329 - 329 355 374 - 371 399 421 - 409 441 465 -
Lo PR 105 112 122 - 111 118 129 - 116 123 134 - 122 129 141 - 127 135 148 - 132 140 153 -
1575
MBh 41.2 42.7 46.7 - 40.2 41.7 45.7 - 39.2 40.7 44.6
- 38.3 39.7 43.5 - 36.4 37.7 41.3 - 33.7 34.9 38.3 -
S/T 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.48 - 0.87 0.73 0.50 - 0.88 0.73 0.51 -
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
kW 2.78 2.84 2.92 - 2.98 3.04 3.13 - 3.15 3.21 3.31 - 3.30 3.37 3.47 - 3.43 3.50 3.61 - 3.54 3.62 3.73 -
Amps
10.2 10.5 10.8 - 11.0 11.3 11.7 - 12.0 12.3 12.7 - 12.8 13.1 13.6 - 13.6 14.0 14.4 - 14.4 14.8 15.3 -
Hi PR 229 246 260 - 257 276 292 - 292 314 332 - 333 358 378 - 374 403 425 - 414 445 470 -
Lo PR 106 113 124 - 112 120 131 - 117 124 136 - 123 131 143 - 129 137 149 - 133 142 155 -
75
1225
MBh 37.5 38.6 41.8 44.9 36.6 37.7 40.8 43.8 35.8 36.8 39.9 42.8 34.9 35.9 38.9 41.7 33.1 34.1 36.9 39.6 30.7 31.6 34.2 36.7
S/T 0.80 0.71 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.91 0.81 0.62 0.40 0.92 0.82 0.62 0.40
∆T 22 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 19 16 11
kW 2.72 2.78 2.86 2.94 2.91 2.97 3.06 3.15 3.08 3.14 3.23 3.33 3.23 3.29 3.39 3.50 3.35 3.42 3.53 3.64 3.46 3.53 3.64 3.76
Amps 10.0 10.2 10.5 10.9 10.8 11.0 11.4 11.8 11.7 11.9 12.3 12.8 12.5 12.8 13.2 13.7 13.3 13.6 14.0 14.6 14.0 14.4 14.9 15.4
Hi PR 222 239 252 263 249 268 283 295 283 305 322 336 323 347 367 383 363 391 413 430 401 432 456 476
Lo PR 103 110 120 128 109 116 127 135 113 121 132 140 119 127 138 147 125 133 145 154 129 137 150 160
1400
MBh 40.6 41.8 45.3 48.6 39.7 40.9 44.2 47.5 38.7 39.9 43.2 46.3 37.8 38.9 42.1 45.2 35.9 37.0 40.0 43.0 33.3 34.2 37.1 39.8
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.61 0.40 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
∆T 22 20 17 12 22 21 17 12
22 21 17 12 23 21 17 12 22 20 17 12 21 19 16 11
kW 2.78 2.84 2.92 3.01 2.98 3.04 3.13 3.22 3.15 3.21 3.31 3.41 3.30 3.37 3.47 3.58 3.43 3.50 3.61 3.72 3.54 3.62 3.73 3.85
Amps
10.2 10.5 10.8 11.2 11.0 11.3 11.7 12.1 12.0 12.3 12.7 13.2 12.8 13.1 13.6 14.1 13.6 14.0 14.4 15.0 14.4 14.8 15.3 15.9
Hi PR 229 246 260 271 257 276 292 305 292 314 332 346 333 358 378 394 374 403 425 444 414 445 470 490
Lo PR 106 113 124 132 112 120 131 139 117 124 136 145 123 131 143 152 129 137 149 159 133 142 155 165
1575
MBh 41.9 43.1 46.6 50.1 40.9 42.1 45.6 48.9 39.9 41.1 44.5 47.7 38.9 40.1 43.4 46.6 37.0 38.1 41.2 44.2 34.3 35.3 38.2 41.0
S/T 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.92 0.82 0.62 0.40 0.95 0.85 0.64 0.41 0.99 0.88 0.67 0.43 1.00 0.89 0.67 0.43
∆T 21 20 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
kW 2.80 2.86 2.94 3.03 3.00 3.06 3.15 3.25 3.17 3.24 3.34 3.44 3.33 3.40 3.50 3.61 3.46 3.53 3.64 3.75 3.57 3.65 3.76 3.88
Amps 10.3 10.6 10.9 11.3 11.1 11.4 11.8 12.2 12.1 12.4 12.8 13.3 12.9 13.2 13.7 14.2 13.8 14.1 14.6 15.1 14.6 14.9 15.4 16.0
Hi PR 231 249 263 274 259 279 295 308 295 318 335 350 336 362 382 398 378 407 430 448 418 450 475 495
Lo PR 107 114 125 133 114 121 132 140 118 126 137 146 124 132 144 153 130 138 151 161 134 143 156 166
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power