Goodman Mfg 10.3 EER Air Conditioner User Manual


 
10 www.goodmanmfg.com SS-GPCC
PRODUCT SPECIFICATIONS
WIRING DIAGRAM — PCC24-36***
FI ELD CONNECTI ON
208/ 230 VAC 1
Ø
USE COPPER
CONDUCTORS
ONLY-
75°C MIN
COMPRESSOR
1Ø WIRING
208/230 VAC 1
Ø
XFMR-R
R
XFMR-C
C
G
NO
NC
COM
WH-7
G
C
XFMR C
XFMR R
R
COM
NC
NO
HI VOLTAGE FIELD
R
CC
COIL
FOLLOWING CHANGE MUST BE MADE:
L2
HI
ELECTRIC HEAT BLOWER TAP
HEAT RELAY
LOW
USE COPPER CONDUCTORS ONLY - 75?C MIN
WARNING:DISCONNECT POWER BEFORE SERVICING.
HORIZ
NUMBER
GN GREEN
PCC24C02*
MED-LOW
G
CAP
HE R M
FAN
OD
COLOR CODE
YL YELLOW
PCC30C02*
Y
G
MED
HIGH
TO HEATER KIT
C
LOW
ACB
CONTACTOR
BK BLACK
230/208
LOW VOLTAGE FIELD
R
HORIZ
MED
LOW
HI VOLTAGE
HORIZ
T1
DOWN
ALTERNATE UNIT POWER REFRIGERANT
R
BLOWER
FOR PROPER OPERATION ON 208 VOLT THE
W2
RD RED
KIT
T2
2
DOWN
DOWN
LPS
PHCB20C1
W
RELAY
LOW
COOLING
RD
HEATER
PHCB05C1
RELAY
GN
CAP
RELAY
COM
L1
HORIZ
LOW VOLTAGE
C
ACCESSORY INSTALLATION INSTRUCTIONS.
OR ORANGE
TAP
HEAT
1
22303801 REV. 1
230 VOLT
4
F
U
S
E
208 VOLT INSTALLATION
LEADS MAY BE USED WITH ELECTRIC
HEAT
LO
CAP
START
DOWN
PHCB10C1
5
COOLING
COMMON
PHCB15C1
COOLING
S
CAP
BU BLUE
24V
SPEED TAP
FAN
BR BROWN
MED HI
MOVE RD6 WIRE FROM TRANSFORMER
HEATER ACCESSORIES. SEE HEATER
W
C
GY GRAY
BK
5
2
ELECTRIC
START
ELECTRIC
W1
HIGH
230 TERMINAL TO 208 TERMINAL.
MODEL
E
COMP
VT VIOLET
FAN RELAY
SWITCH
WH WHITE
Y
COOLING
TAP
MED
LOW
HIGH
HIGH
HIGHLOW
LOW
MED
HIGH
MED
HIGH
MED
HIGH
MED
LOW
MED
LOW
MED-HIGH
PCC36C02*
MED
LOW
HIGH HIGH
LOW
LOW
MED
HIGH
MED
HIGH
MED
LOW
MED LOW
RD-27
RD
RD-6
7
ELECTRIC
4
T2
FAN
YL-27
FAN
VT-14(COMMON)
C
BU-34
HERM
L2
C
TRANSF ORMER
BU
BK-27
BR-21
GY-70
BU-34
VT-14
TERMINAL BOARD
BR
YL/BK
VT
TO
PIN 5
BR-11
HI
W
GND
LOW
Y
YL/BK
L1
S
3
VT-20
12
O
RD-13
BK-26
RD-11
PIN 8
HEATER
PIN 1
PIN 2
6
MED HI
6
PIN 7
BLOWER
2
5
RELAY
31
BU-1
RD
YL
RD-13
CAPACITOR
G
CIRCULATION 2
BU-9
COMMON
RD
(ACB)
KITS
SWITCH
PIN 6
RD-10
BU-23
4
5
BK-26
2
RD-27
VIEW A-A
R
BU-23(HEAT)
10
33
GY-28
BR
1
CONTACTOR (CC)
CAPACITOR
1
L2
A
MOTOR
LINE
LOAD
VT-18
RD-22
VT-7
VT-18
AIR
3
PIN 9
5
L1
1
RD
A
(CAP)
BU
HEAT
SWITCH (LPS)
LOW PRESSURE
BU-9
RD-31
7
REL AY
23
230
COOLING
3
GND
BU-9
COM
20
PIN 4
O.D.
208
R
T1
31
9 8
PIN 3
VT-16
RD-24(COOL)
COM
4
MED LOW
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date schematic.
WARNING
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.