Glowworm Lighting 300 I Water Heater User Manual


 
8
1 Product Specications
1.1 Intended use
The Glow-worm Flurocyl 200 l, Flurocyl 250 l and Flurocyl 300
l are unvented, indirectly heated hot water cylinders for use
with solar systems and boilers for the provision of domestic
hot water.
IMPORTANT: Risk of damage! The appliances may only
be used to heat up potable water. Damage to the appliance
due to corrosion cannot be excluded if the water does not
correspond to the specications of the water ordinance.
Any other use or extended use is considered to be improper.
The manufacturer/supplier is not liable for any resulting
damage.
Intended use includes the observance of the instructions and
the adherence to the servicing requirements.
1.2 Data badge
The data badge has been applied to the top of the solar
cylinder by the manufacturer.
1.3 Safety devices
The Flurocyl solar cylinder has been provided with all safety
and control devices suitable for operation as part of an
unvented domestic hot water supply system.
Temperature and pressure relief valve (95°C, 7 bar)
Pressure limiting valve (3.5 bar) with line strainer
Expansion relief valve (one port valve, 6.0 bar)
Thermal cut out set to 90°C, connected to the solar pump in
order to isolate this heat source in the event of failure of the
solar control.
Thermal cut out of the immersion heater
Thermal cut out set to 90°C, connected to the motorised 2
port valve, in order to isolate the primary heat source in the
event of failure of the domestic water thermostat.
1.4 Safety regulations
This product has been checked for adherence to the building
regulations for unvented hot water cylinder systems. It may
not be changed or modied in any way whatsoever.
It should be installed by a qualied specialist, who should
observe the applicable regulations of the local authorities, the
building regulations, the building regulations for Scotland, the
building regulations for Northern Ireland and the directives of
the local water supply companies. Only original spare parts
may be used for the replacement of parts.
1.5 Contents
Check the contents of the pack, see diagram 2.1.
Make sure the cylinder is stored in an upright position in a dry
environment prior to its installation.
1.6 Transport
A cylinder carrying handle is supplied to make the transport to
the installation site easier.
Fasten the carrying handle to the hot water outlet connection
of the solar cylinder.
CARRYING
HANDLE
14180
Diagram 1.4
Carrier handle
1.7 Solar Cylinder Charicteristics
Flurocyl solar cylinders are available in three sizes: 200, 250
and 300 litres. The containers are made of stainless steel
and insulated with EPS.The cylinders are equipped with all
necessary cold and hot water control devices and a motorised
2 port valve.
The Flurocyl cylinders are operated at the pressure of the
water supply pipe and do not need a cold water tank for their
supply. They have hot and cold water connections of 22 mm
diameter. A cold water supply of appropriate pressure and
ow rate is required to operate the solar cylinder ideally, refer
to section 2.6.
Temperature control
The solar water heating control thermostat is part of the solar
control with sensor attached to the Flurocyl solar cylinder.
The cylinder includes the boiler and imersion heater control
thermostats that are factory tted and set.
A themostatic mixing valve must be tted to the outlet of the
cylinder and must be adjusted to the desired domestic hot
water temperature.
The cylinder also includes the solar, boiler and immersion
heater thermal cut outs that are factory tted and set.
The solar pump must be connected to the solar control via
the solar thermal cut out (TCO), It ensures the solar pump is
switched off if the hot water temperature in the cylinder rises
above 90°C.
Immersion heater
The Flurocyl solar cylinders are equipped with an additional
immersion heater of 3 kW, including the control thermostat
and thermal cut out. The immersion heater is situated behind
the front plate.
NOTE: In the event of a replacement, only the right immersion
heater equipped with a thermal cut out fur overheating
protection may be used.