Genie PMX-IC B Garage Door Opener User Manual


 
CAUTION
WARNING
Wall console
Wall button
OR
Fig. 4-2
#6 x 1
pan head screws
Fig. 4-3
MORE
T
MENT
OPEN
PUSH
LIMITS
TO SET
G4
Y3
B2
W1
1. Run wire from power head to wall control.
Place the wall control:
In sight of door.
At least 5 feet from floor, so small children can
not reach it.
Away from moving parts of door and
door hardware.
Use staples to fasten wire to ceiling and wall.
2. Remove 1/2 insulation from each wire
(Fig. 3-6)(pg. 19).
3. Attach wires to terminals (Stealth Fig. 4-1a)
(MAX Fig. 4-1b).
Loosen, but Do Not remove screw from terminal.
For Stealth.
Connect striped wires to terminal 2 on power
head and B on wall control.
Connect white wire to terminal 1 on power
head and W on wall control.
For MAX.
Connect striped wires to terminal 1 on power
head and B on wall control.
Connect white wire to terminal 2 on power
head and W on wall control.
4. Mount wall control (Fig. 4-2).
Use two pan head screws.
5. Mount entrapment warning label.
Remove protective backing and stick near
wall control.
Use tacks or staples to permanently mount Label.
Make sure everyone reads and follows WARNINGS.
NOTE: Additional wall controls are available from your
dealer. ONLY ONE OF YOUR WALL CONTROLS MAY BE THE
LIGHTED TYPE. If you have a lighted wall control, all your
additional controls must be un-lighted. More than one
lighted wall control per operator will cause a malfunction.
Power cord must be unplugged before attaching
wires. Be sure wire ends do not touch each other
or other terminals.
Use of any other wall control will cause the
light not to work and could cause door to
operate by surprise.
Cut or pinched wires can cause door operator
to malfunction. Drive staples just tight enough
to hold wire.
Fig. 4-1a
1
2
3
4
W
B
BW
White
Striped
Wall
console
terminals
Wall
button
terminals
Power head
terminals
Back view
Back view
1
2
3
4
White
Striped
OR
Power
head
ferminals
Rear view of
power head
Fig. 4-1b
NEC
CLASS 2
1
2
3
4
5
6
MORE
FORCE
PUSH
BUTTON
SAFETY
BEAM
LIMIT
SET
OPEN
FORCE
CLOSE
FORCE
RADIO
SIGNAL
LEARN
CODE
COM
DO NOT
PUSH
LIMIT SET
UNLESS
DOOR IS
ATTACHED
NOTE:
USE ONLY WITH
SERIES II CONTROLS
CLOSE
MORE
OPEN
MORE
OSE OPEN
LIMIT ADJUSTMENT
U.S. Patent No. 5,243,784
5,221,869
CSS
1
2
3
W
B
BW
Striped
White
Wall
console
terminals
Wall
button
terminals
Power head
terminals
power head
terminals
Back view
Back view
Front view of
power head
CSS
1
2
3
Striped
White
EITHER
20
4
...
WALL CONTROL INSTALLATION
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM
Independent Light Control
Controls door operator lights from inside garage
Energy-Saver shut-off turns off light 5 minutes after
door activation
Vacation Locking Switch
LOCK disables controls after door is completely closed
UNLOCK allows controls to work normally
Lighted Button
Shows system is powered
Lights when Security Lock
Switch is in UNLOCK position
Goes out when Security Lock
Switch is in LOCK position
Door Control Button
Open and closes door from
inside garage
1
4
3
2