GE QS1800V Heat Pump User Manual


 
6.0 FIELD MAINTENANCE
6.1 Flow-Cooled Mot
or and Liquid End - Tonkaflo Service Policy
WARNING: FIELD SERVICE OF THE FLOW-COOLED MOTOR OR LIQUID IS NOT
RECOMMENDED. If a liquid end is damaged by running the pump dry,
inadequate flow, deadheading, cavitation or other reasons, return it
with the motor to the factory for repair. The motor module and liquid
end may be separated for easier shipping. See Section 6.2 (Liquid End
Removal and Installation) for liquid end removal.
If a repair at the factory is desired, call the factory for a Return Goods Authorization
(RGA) number and follow the directions provided by a GE Customer Service represen-
tative. See Section 7.0 [Return Goods Authorization (RGA) Procedure] for more details.
6.2 Liquid End Remov
al and Installation
WARNING: DISCONNECT POWER SOURCE BEFORE ATTEMPTING ANY TYPE OF
FIELD SERVICE. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY
OR DEATH!
Figure 6.8
Liquid End and
Motor Module
(QS2825V Shown)
20
Liquid End
Remove Bolts
and Washers
(4PL)
Motor Module