GE Merlin Water System User Manual


 
24 DIMENSIONS
Rev B
DIMENSIONS
Performance Specifications
1
,
2
Minimum Maximum Average
Permeate Flow Rate 0.33 gals/min (1.25 Lpm) 0.75 gals/min (2.84 Lpm) 0.50 gals/min (1.89 Lpm)
TDS Rejection (NaCl)
3
90% 99% 93%
Minimum and Maximum Operating Conditions
Condition Minimum Maximum
Inlet Pressure 40 psi (2.76 bar) 80 psi (5.52 bar)
Inlet Temperature 40°F (4.44°C) 100°F (37.78°C)
Inlet TDS 50 mg/L 2,000 mg/L
Inlet Hardness 0 mg/L (0 grain) 171 mg/L (10 grain)
Inlet Chlorine 0 mg/L 1.0 mg/L
Inlet Iron 0 mg/L 0.1 mg/L
Inlet Manganese 0 mg/L 0.05 mg/L
Inlet pH 4 10
Inlet Turbidity 0 1 NTU
1. Based on 50 psi (3.44 bar), 77°F (25°C), 750 mg/L NaCl, 23.7% Recovery
2. System is designed for use on potable water systems only.
3. Specifications based on GE Osmonics testing data. For complete WQA test results to ANSI/NSF 58 standard,
see the Merlin Performance Data Sheet P/N 1263717.