GE GXSV65F Water System User Manual


 
Installation Instructions.
Important Installation Recommendations
WARNING: Read entire manual. Failure to follow all guides
and rules could cause personal injury or property damage.
Check with your local public works department for plumbing codes.
You must follow their guides as you install the Water Filtration
system.
Tools and Materials Required for Installation
Phillips screwdriver
Two (2) adjustable wrenches
Electric drill and drill bit to drill 3/4hole (type as required)
if mounting hole is needed for faucet
1/16drill bit (optional for pilot holes)
Tape measure
If your main water line is a rigid pipe, you will require a compression
fitting and possibly other plumbing hardware to complete the installation.
CAUTION: To avoid damaging the sink, consult a qualified
plumber or installer for drilling procedures. Special drill bits may be needed
for porcelain or stainless steel.
Contents Included with the Product
Water filter system assembly, including mounting screw and double-
sided tape
Feed water adapter
Faucet assembly with electronic base monitor and tubing
Instrucciones de instalación.
Recomendaciones importantes para la instalación
ADVERTENCIA: Lea el manual completo. No seguir todas
las pautas y reglas podría causar lesiones personales y a la propiedad.
Consulte con su departamento local de obras públicas para los
códigos de plomería. Usted debe seguir estas pautas a medida que
instala el sistema de filtración de agua.
Herramientas y materiales necesarios para la
instalación
Destornillador de estrella
Dos (2) llaves ajustables
Taladro eléctrico y broca para el taladro para perforar un orificio de 3/4
para el grifo (del tipo necesario)
Broca de 1/16para taladro (opcional para orificios piloto)
Cinta métrica
Si su línea de agua principal es de tubería rígida, usted necesitará un
accesorio de compresión y posiblemente alguna otra herramienta de
plomería para completar la instalación.
PRECAUCIÓN: Para evitar daños al lavaplatos, consulte
con un plomero o instalador calificado para los procedimientos de perforación.
Podrían necesitarse brocas especiales para porcelana o acero inoxidable.
Contenido incluido con el producto
Ensambladura del sistema de filtración de agua, incluyendo el tornillo de
instalación y cinta con doble adhesivo
Adaptador para la alimentación de agua
Ensambladura del grifo con un monitor de base electrónico y tubería
7
1
Influent challenge levels are average influent concentrations determined in surrogate qualification testing. /
Los niveles de reto influyente son concentraciones influyentes promedio determinadas en pruebas de
calificación sustitutas.
2
µg/L means Micrograms Per Liter. / µg/L significa microgramos por litro.
3
Maximum product water level was not observed but was set at the detection limit of the analysis. / El nivel
máximo del agua del producto no se observó pero fue colocado a un límite de detección para el análisis.
4
Maximum product level is set at a value determined in surrogate qualification testing. / El nivel máximo del
producto es colocado a un valor determinado por la prueba de calificación sustituta.
5
Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough
point as determined in surrogate qualification testing. / El porcentaje de la reducción química y el nivel
máximo del agua del producto calculado a un punto de ruptura de 95% de cloroformo según lo
determinado en la prueba de calificación sustituta.
6
The surrogate test results for heptachlor Epoxide demonstrated a 98% reduction. These data were used to
calculate an upper occurrence concentration, which would produce a maximum product water level at the MCL. /
Los resultados de la prueba de sustitución para el Epoxido heptacloro demostraron una reducción de 98%. Estos
datos fueron usados para calcular la ocurrencia de una concentración superior, la que produciría un nivel máximo
de agua del producto en el MCL.
Organic Chemicals Reduced by Chloroform Surrogate Testing / Químicos orgánicos reducidos por la prueba sustituta de cloroformo
Avg. / Promedio
1
Max. Effluent /
Contaminant / Contaminante Influent / Influyente (µg/L)
2
Effluyente (µg/L)
2
Alachlor 50 1.0
3
Atrazine 100 3.0
3
Benzene 81 1.0
3
Carbofuran 190 1.0
3
Carbon Tetrachloride 78 1.8
4
Chlorobenzene 77 1.0
3
Chloropicrin 15 0.2
4
2,4-D 110 1.7
4
Dibromochloropropane (DBCP) 52 0.02
3
o-Dichlorobenzene 80 1.0
3
p-Dichlorobenzene 40 1.0
3
1,2-Dichloroethane 88 4.8
5
1,1-Dichloroethylene 83 1.0
3
cis-1,2-Dichloroethylene 170 0.5
3
trans-1,2-Dichloroethylene 86 1.0
3
1,2-Dichloropropane 80 1.0
3
cis-1,3-Dichloropropylene 79 1.0
3
Dinoseb 170 0.2
4
Endrin 53 0.59
4
Ethylbenzene 88 1.0
3
Ethylene Dibromide (EDB) 44 0.02
3
Haloacetonitriles (HAN):
Bromochloroacetonitrile 22 0.5
4
Dibromoacetonitrile 24 0.6
4
Dichloroacetonitrile 9.6 0.2
4
Trichloroacetonitrile 15 0.3
4
Avg. / Promedio
1
Max. Effluent /
Contaminant / Contaminante Influent / Influyente (µg/L)
2
Effluyente (µg/L)
2
Haloketones (HK):
1,1-dichloro-2-propanone 7.2 0.1
4
1,1,1-trichloro-2-propanone 8.2
6
0.3
4
Heptachlor (H-34, Heptox) 80 0.4
3
Heptachlor Epoxide 10.7
6
0.2
6
Hexachlorobutadiene 44 1.0
3
Hexachlorocyclopentadiene 60 0.002
3
Lindane 55 0.01
3
Methoxychlor 50 0.1
3
Pentachlorophenol 96 1.0
3
Simazine 120 4.0
3
Styrene 150 0.5
3
1,1,2,2-Tetrachloroethane 81 1.0
3
Tetrachloroethylene 81 1.0
3
Toluene 78 1.0
3
2,4,5-TP (silvex) 270 1.6
3
Tribromoacetic acid 42 1.0
3
1,2,4-Trichlorobenzene 160 0.5
3
1,1,1-Trichloroethane 84 4.6
4
1,1,2-Trichloroethane 150 0.5
3
Trichlorothylene 180 1.0
3
Trihalomethanes (includes): 300 15
Chloroform (surrogate chemical)
Bromoform
Bromodichloromethane
Chlorodibromomethane
Xylenes (total) 70 1.0
3
Testing was performed under standard laboratory conditions; actual performance may vary. / La prueba fue llevada a cabo bajo condiciones de laboratorios estándares; el rendimiento real podría variar.
NOTE: Substances reduced are not necessarily in your water. Filter must be maintained according to manufacturer’s instructions, including replacement of filter cartridges. / NOTA: Las sustancias reducidas no están necesariamente en su
agua. El filtro debe mantenerse de acuerdo con las instrucciones del fabricante, incluyendo los cartuchos de reemplazo.
WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that contain
filterable cysts. / ADVERTENCIA: No use con agua que no sea microbiológicamente segura o de calidad desconocida sin desinfección adecuada antes y después del sistema. Los sistemas certificados para la reducción del quiste
podrían usarse en aguas desinfectadas que contienen quistes filtrables.
Performance Data Sheet. Hoja de datos de funcionamiento.