GE GNPR40L Water System User Manual


 
23
ge.com
The following table represents preset values programmed into
the system at the factory for both levels for the model shown.
Required Parameters
Name Description GNPR40L GNPR48L
P1 Time of day Set in field Set in field
P2 Time of regeneration 2:00 a.m. 2:00 a.m.
P3 Hardness Set in field (25 grains) Set in field (25 grains)
P4 Salt amount 7.5 lbs 9.0 lbs
P5 Capacity 24.4 Kgr 26.1 Kgr
Advanced Programming Parameters
Name Description GNPR40L GNPR48L
P6 Refill controller 0.33 gpm 0.33 gpm
P7 Brine draw value 15 min. 16 min.
P8 Not used N/A N/A
P9 Backwash time 12 min. 12 min.
P10 Slow rinse time 67 min. 83 min.
P11 Fast rinse time 4.0 min. 4.0 min.
P12 Units of measure 0 0
P13 Clock mode 0 0
P14 Calendar override 0 0
P15 Reserve type 0 0
P16 Fixed reserve capacity N/A N/A
or initial average value
P17 Operation type 1 1
P18 Salt/capacity change 0 0
lock out
P19 Factory defaults 9 9
Default Settings