GE 5500 Air Conditioner User Manual


 
The satisfactory operation of this air condition-
er is dependent upon it being installed in a wall
case, and used with an exterior grille, both
specifically designed for use with this unit.
Use
with an incorrect wall case or with an incorrect
grille may result in poor performance and
could cause damage to the unit. If you are not
sure if you have the correct wall case and the
rear grille please contact the company where
you purchased the unit.
For personal safety, this air conditioner must be
properly grounded.
It is important to have the wall outlet and circuit
checked by a qualified electrician if there is any
doubt as to whether a proper ground exists.
Follow National Electrical Code (NEC) or local
codes and ordinances.
CAUTION:
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord of this
air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
We recommend that the 230/208-volt, 60 Hz
models be installed on their own single branch
circuit supplying 230/208-volt a.c., protected
with a time delay fuse or circuit breaker.
PPaarraalllleell PPeerrppeennddiiccuullaarr TTaannddeemm
115V. 230/208V. 230/208V.
15 Amp. 20 Amp. 15Amp.
This is recommended for best performance and