POWER CONNECTION CHART
230/208 Volt
Power Supply Kits
with Current Leakage Wall Plug Heater Wattage
Detection Device Configuration Circuit Protective Device @ 230/208 Volts
RAK3153 Tandem 15-Amp Time-Delay Fuse or Breaker 2.55/2.09 KW
RAK3203 Perpendicular 20-Amp Time-Delay Fuse or Breaker 3.45/2.82 KW
RAK3303* Large Tandem 30-Amp Time-Delay Fuse or Breaker 5.00/4.10 KW
230/208 Volt Heater Wattage
Power Supply Kits Circuit Protective Device @ 230/208 Volts
RAK4157 15-Amp Time-Delay Fuse or Breaker 2.55 KW/2.09 KW
RAK4207 20-Amp Time-Delay Fuse or Breaker 3.45 KW/2.82 KW
RAK4307* 30-Amp Time-Delay Fuse or Breaker 5.00 KW/4.10 KW
265 Volt Heater Wattage
Power Supply Kits Circuit Protective Device @ 265 Volts
RAK5157 15-Amp Time-Delay Fuse or Breaker 2.55 KW
RAK5207 20-Amp Time-Delay Fuse or Breaker 3.45 KW
RAK5307* 30-Amp Time-Delay Fuse or Breaker 5.00 KW
*Not approved for use on 7000 BTUH units.
Power Cord Connections
Direct Connections