It is not hard to fine-tune your softener, but it does take a few minutes of your time to do it right.
Read the following carefully.
To have soft water all the time, the softener must regenerate, or recharge a certain number of
times in each seven day period. How many times to regenerate (set the timer) depends on three
things:
The number of people in your home tells you how much water is used.
The grains per gallon (GPG) hardness of your water supply.
NOTE:
If your water supply contains iron, compensate for it by adding to the water hardness
number.
For example, assume your water is 15 gpg hard and contains 2 ppm iron. Add 5 to
the
hardness number for each 1 ppm of iron thus, making the example water hardness number 25 .
15 gpg hardness
2 ppm iron x 5 = 10 +10
(times) 25 HARDNESS NUMBER
How much salt used in each regeneration is determined by the length of the fill cycle. See
the
Regeneration Chart
section.
3
2
1
About regenerating the system.
Customer Service Troubleshooting Tips
Installation Instructions
Safety InstructionsCustomer Service Troubleshooting Tips
Operating Instructions
Safety InstructionsCustomer Service Troubleshooting Tips Safety Instructions
16
Setting the Timer for Days and Fill Minutes of Regeneration
NOTE:
The timer is factory set for Monday, Wednesday and Saturday with regenerations starting
at 2:00 AM. Fill time is factory set for 16 minutes.
Set days and time of regeneration or recharge.
Step 1—
Press the
REGENERATION TIME
button once to display the factory set regeneration days
and starting time (flashing). To change the regeneration start time, do
Step 2
following
this. Otherwise go to
Step 3.
NOTE:
See
Automatic Bypass
section, when choosing a regeneration starting time other
than 2:00 AM.
Step 2—
Press the
SET/CLEAR
button until the desired regeneration starting time shows in the
display.
NOTE:
Press
SET/CLEAR
and quickly release to move the display ahead 1 hour at a
time.
Or, hold the
SET/CLEAR
button to move display ahead 2 hours each
second.
Step 3—
Press the
REGENERATION DAY
button and
SUnday
begins to flash.
If you do want regenerations on Sunday, see the
Regeneration Chart
, press the
SET/CLEAR
button to display
ON.
If you do
NOT
want regenerations on Sunday, press
SET/CLEAR
button to display
OFF.
Step 4—
Press
REGENERATION DAY
button again to display a flashing
MOnday
and
ON
(factory set
recharge). Use the
SET/CLEAR
button to change display from
ON
to
OFF
or from
OFF
to
ON.
Step 5—
Press
RECHARGE DAY
button to display a flashing
TUesday, WEdnesday,
etc., each time
using the
SET/CLEAR
button to display either
ON
or
OFF
as needed.
Set the Fill Cycle Minutes
Step 1—
Press and hold the
REGENERATION TIME
button until
FILL
shows in the display, then
release button. After a few seconds, the fill cycle minutes (factory setting…16) will flash.
Step 2—
Press the
SET/CLEAR
button to set the minutes of fill cycle needed, as shown in the
Regeneration Chart
section.
NOTE:
You may get hard water between regenerations if you set the timer for fewer fill
minutes than the
Regeneration Chart
shows you to set. A higher setting than needed will
waste salt.
NOTE:
Press
SET/CLEAR
and quickly release to move the display ahead 1 minute at a time.
Or, hold the
SET/CLEAR
button to move the display ahead 2 minutes each second.
The
display begins over at 0 after passing 59.
2
1
AM
MO
WE SA
REGENERATE NOW
VACATION ON/OFF
TOUCH
HOLD
SET/CLEAR
TIME/DAY
REGENERATION
DAY
REGENERATION
TIME
Write in your results here.
1. M T W TH F S SU
—circle suggested days—
Suggested days to regenerate
2.
Fill Cycle minutes needed