RAK204 (AZ Series*—2200, 2500, 3200 and 3500 only)
Standard Sub-Bases WITHOUT power cord included
TheRAK204sub-baseismadeofheavy-gaugesteeltoprovidesupportofthewallcase.
Ithasfullbaseenclosurewithbreakawaysidechannels,simpleconnectiontowallcase
and4-pointlevelinglegs.Thesub-basewilladapttoserviceconduit,circuitbreakers
andreceptaclesupto30amps.Itmayalsobeusedasanon-electricalsub-baseto
provide support for the unit.
Circuit
Kit No. Sub-Base Ampacity Chaseway Power Cord
RAK204U** Standard N/A NotIncluded NotIncluded
RAK204D20 Sub-Base230/208V 15&20 Included NotIncluded
RAK204D30 Sub-Base230/208V 30 Included NotIncluded
RAK204E15 Sub-Base265/277V 15 Included NotIncluded
RAK204E20 Sub-Base265/277V 20 Included NotIncluded
RAK204E30 Sub-Base265/277V 30 Included NotIncluded
Power cord and junction box
not included with sub-base.
Chaseway
Zoneline units
RAK205CW
(AZ Series*—2200, 2500, 2800, 2900, 3200, 3500, 3800, 3900, 4100,
5200, 5500, 5800 and 6100 only)
Chaseway
Chaseway for wiring containment between junction box on
chassisandRAK204Usub-base.
Chaseway
RAK204 (AZ Series*—2800, 2900, 3800, 3900, 4100, 5200, 5500, 5800
and 6100 only)
Standard Sub-Bases WITH power cord included
TheRAK204sub-baseismadeofheavy-gaugesteeltoprovidesupportofthewallcase.
Ithasfullbaseenclosurewithbreakawaysidechannels,simpleconnectiontowallcaseand4-point
levelinglegs.Thesub-basewilladapttoserviceconduit,circuitbreakersandreceptaclesupto30
amps.Itmayalsobeusedasanon-electricalsub-basetoprovidesupportfortheunit.
Circuit
Kit No. Sub-Base Ampacity Chaseway Power Cord
RAK204D15P Sub-Base230/208V 15 Included Included
RAK204D20P Sub-Base230/208V 20 Included Included
RAK204D30P Sub-Base230/208V 30 Included Included
RAK5157/5207/5307
(AZ Series*—2800, 2900, 3800, 3900, 4100, 5500, 5800, 6100)
265/277-Volt Universal Power Supply Kit
• 9-pinconnectorwiththree7"12-gaugeconductorwires
Circuit
Kit No. Volts Heater Wattage Ampacity
RAK5157 265/277 2.4 kw 15
RAK5207 265/277 3.4 kw 20
RAK5307 265/277 4.8 kw 30
* A-B Series: Zoneline units built before 1987 – Zoneline I, II, III, and IV; AZC Series: Zoneline units built from 1987 to 1992 – includes AZR Series – Zoneline 1000, 2000, 2500, 2700, 3000,
4000, 5000; AZ Series: Zoneline units built after 1992 – Zoneline 2100, 3100, 2600, 5100 / Zoneline 2200, 3200, 5200 / Zoneline 2500, 3500, 5500 / Zoneline 2800, 2900, 3800, 3900, 4100,
5800, 6100, 7500, 8500.
**RAK204UMaybeusedwithAZCandAZ2100,3100,2600and5100.
†ThepowerconnectionkitdeterminestheheaterwattageandcurrentrequirementswhenitispluggedintotheZonelineunit.NOTE:7,000BTUmodelsdonothave5,000-wattheaters.