8
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS:
STUDIO 1 CF: STUDIO 2 CF:
8700CFCHEC 8701CFCHEC
P8700CFCHEC P8701CFCHEC
Model Gas CAT. Gas Type Working
Pressure
Aeration Injector Gas Rate
m
3
/h
Input kW (Gross) Country
High Low
Studio 1
CF
12H Natural G20 20mbar 6 x 10 390 0.657 6.9 4.0 GB, IE
Studio 1
CF
13+
Propane G31 37mbar
Open both
sides
185
0.257
6.9 4.0 GB, IE
Butane G30 29mbar 0.197
Model Gas
CAT.
Gas Type Working
Pressure
Aeration Injector Gas Rate
m
3
/h
Input kW (Gross) Country
High Low
Studio 2
CF
12H Natural G20 20mbar 9 x 15
offset
530 0.791 8.3 4.2 GB, IE
Studio 2
CF
13+
Propane G31 37mbar One side open
+ 10 x 16 225
0.312
8.3 4.2 GB, IE
Butane G30 29mbar 0.238
Open both
sides
Studio 1 Efciency Class 2 - 70% NO
x
Class 4
Studio 2 Efciency Class 2 - 78% NO
x
Class 4
Weight Fire Only Prol Bauhaus Steel Flue Size
TOP EXIT REAR EXIT
Studio 1 52 Kg 3.6 Kg 3.6Kg 18.5Kg 127mm ø 178mm ø minimum
Studio 2 60Kg 4.6Kg 4.6Kg 21.8Kg Gas Inlet Connection Size = 8mm ø
Minimum Flue Specication = T260/N2/0/D/1
Minimum Flue Temp = 220
o
C