Stovax 8519-P8519 Indoor Fireplace User Manual


 
10
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
Packing Checklist
Qty Description
1 Stove
1 Flue Blanking plate
1 Flue In fill plate
1 Coal set*
1 Flame Baffle*
1 Front Coal*
1 Fixing kit containing
1 Instruction Manual
2 Wood screws
2 Rawlplugs
1 Box spanner
*Packed in appliance
ModelCAT. Gas Gas Type Working
Pressure
NOX
Class
Aeration Injector Gas Rate
m3h
Input kW (Gross) Country
High Low
Small: 8541- 8517 - Clarendon I
2H
Naural Gas G20 20 mbar 5 ø7 mm 260 0.433 4.55
Gross
2.5
Gross
GB,IE
P8541- P8517 - Clarendon
I
3+
LPG Propane G31
LPG Butane G30
37 mbar
29 mbar
5 ø13 mm 120
0.173
0.131
4.60
Gross
2.5
Gross
GB,IE
Medium: 8542- 8518 - Clarendon
8513-8522 - Ashdon
I
2H
Naural Gas G20 20 mbar 5 ø11 mm 375 0.639
6.60
Gross
3.25
Gross
GB,IE
P8542-P8518 - Clarendon
P8513-P8522 - Ashdon
I
3+
LPG Propane G31
LPG Butane G30
37 mbar
29 mbar
5 ø15.5 x 2 170
0.237
0.18
6.30
Gross
3.25
Gross
GB,IE
Large: 8543-8519 - Clarendon
I
2H
Naural Gas G20 20 mbar 5 ø13 mm 560 0.484
8.90
Gross
4.0
Gross
GB,IE
P8543- P8519- Clarendon
I
3+
LPG Propane G31
LPG Butane G30
37 mbar
29 mbar
5
ø15.5 x 2
ø13.0 X 1
240
0.35
0.266
9.30
Gross
4.0
Gross
GB,IE
Efficiency Class II
Flue Outlet Size 127 mm (5”) ø
Gas Inlet Connection Size 8 mm ø
Minimum flue specification T260/N2/O/D/1
Maximum flue temperature 180°C
A B C D E F
ins mm ins mm ins mm ins mm ins mm ins mm
Small
17 431 23
12
589 13
12
342 16 404 5 125
Medium
25
34
654 25
34
652 16
34
427 18
14
463 5 126 3
12
90
Large
30
58
779 28 710 18
12
468 20
38
517 6
12
166