Gas-Fired Products ETS Series Electric Heater User Manual


 
MODEL
BTU/HR
INPUT
MODEL
ETS/U 130 130,000 X X X
ETS/U 140 140,000 X X
ETS/U 150 150,000 X X
ETS/U 160 160,000 X X
ETS/U 175 175,000 X X
ETS/U 180 180,000 X X X X
ETS/U 200 200,000 X X X X
ETS/U 225 225,000 X X X X
ETS/U 250 250,000 X X X X
ETS/U 40 40,000 X X
ETS/U 50 50,000 X X X
ETS/U 60 60,000 X X
ETS/U 75 75,000 X X
ETS/U 80 80,000 X X
ETS/U 90 90,000 X X
ETS/U 100 100,000 X X
ETS/U 110 110,000 X X
ETS/U 120 120,000 X X
ETS/U 125 125,000 X X X
MODEL SELECTIONS
GENERAL FEATURES
19 different Btu/hr sizes and more than 100
different configurations to custom design
your infrared heating system.
CSA design certified
Vented or indirect vented operation
Sidewall or through-the-roof venting
Natural and propane gas models
PULL THROUGH SYSTEM
Products of combustion are pulled
through the combustion chamber for
increased radiant efficiency and greater
safety
No draft hoods, totally enclosed
combustion chamber
Heavy-duty draft inducer with permanently
lubricated, totally enclosed, fan cooled,
and heavy-duty ball bearing motor for
maintenance-free operation
Draft inducer can be rotated 45° or 90°
for sidewall venting
BURNER SYSTEM
Heavy-duty cast iron burner
10-year limited warranty on burner
Inside or outside air for combustion
Up to 50 ft. outside combustion air duct
capability
Standard 6” combustion air duct opening
Reliable direct spark ignition system and
100% gas shut-off safety control
30-second pre-purge prior to ignition
State-of-the-art step opening redundant
combination gas valve for quiet ignition
and added safety
Diaphragm air switch for proof of venting
before gas flow and ignition
Diagnostic monitoring light system
Burner inspection sight glass
RADIANT EMITTER TUBE SYSTEM
4” O.D. heavy-duty calorized aluminized
steel or alumi-therm steel combustion
chamber (10 feet) and heavy duty hot-
rolled steel emitter tubes
3-year limited warranty on the emitter
tubes
Suitable for horizontal or angle mounting
up to 45°
Optional 90° elbows
Up to 75 feet sidewall vent capacity
REFLECTOR SYSTEM
Highly efficient aluminum reflectors with
reflectivity rating of 97.5%
Optional end, corner, side and U-bend
reflectors
Optional decorative grille
Individual reflectors can be rotated up to
45° to direct heat where needed
Easy-to-use mounting brackets
TOTAL EMITTER LUBE LENGTH*
15 FT** 20 FT 30 FT 40 FT 50 FT
ETS/ETU SERIES FEATURES
TOTAL EMITTER LUBE LENGTH*
30 FT 40 FT 50 FT 60 FT 70 FT 80 FT
NOTE: For all installations higher than
2000 ft. above sea level, please consult
the factory regarding recommended
derating of heaters.
GAS
TYPE
NATURAL 3.5” W.C. 5” W.C* 14” W.C.
PROPANE 10” W.C. 11” W.C.** 14” W.C.
BURNER
PRESSURE
VOLTAGE
AMPS
IGNITION
TYPE
MIN MAX
120 VAC
60 HZ
2.6
DIRECT
SPARK
*Indicate model number based on Btu/hr input (e.g., 100,000 Btu/hr), total emitter length, (e.g., 40 feet) and gas type (e.g., natural gas). The
unit selection for a straight tube would be ETS100-40-N and for a U-tube would be ETU100-40-N. **Available only on ETS models.
*7” W.C. for ETS/ETU (180-250) **12” W.C. for ETS/ETU (180-250)
SUPPLY PRESSURE
BTU/HR
INPUT