En-4
: HIGH
: MED
: LOW
TIMER
MODE
SET
ZONE
START/STOP
CLOCK ADJUST
SET TIME TEMP./DAY FAN
CONTROL
MASTER
CONTROL
DAY OFF
ENERGY SAVE
°F
NON STOP
AM CLOCK
AUTO
To Set the Fan Speed
Press the FAN CONTROL button to select the fan speed.
AUTO HIGH MED LOW
When set to AUTO:
* Heating : Fan operates so as to optimally circulate warmed air.
However, the fan will operate at very low speed when the tem-
perature of the air issued from the indoor unit is low.
Cooling : As the room temperature approaches that of the thermostat set-
ting, the fan speed becomes slower.
Fan : The fan alternately turns on and off; when on, the fan runs at the
low fan speed.
The fan will operate at a very low setting during Monitor operation.
To Stop Operation
Press the START/STOP button.
The remote controller’s operation lamp (green) will go out.
The display contents disappear and only the current time is displayed.
Example: When set to HIGH
Setting temperature
Thermostat control
Dry Operation
Cooling Operation
About Mode Operation
AUTO:
COOLING MODEL
● When the room temperature is 4 °F higher than the set temperature, the mode
will switch between Cooling and Drying.
● During the Drying mode operation, the FAN setting should be switched to LOW
for a gently cooling effect during which the fan may temporarily stop rotating.
● If the mode automatically selected by the unit is not satisfactory, see page 3 for
instructions on changing the mode setting (COOL, FAN).
4°F
Instructions relating to heating(*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
OPERATION
AUTO (* AUTO CHANGEOVER):
HEAT & COOL MODEL (Reverse cycle)
● When AUTO CHANGEOVER is selected, the air conditioner selects the appropriate operation mode (Cooling or Heating)
according to your room’s present temperature.
● When AUTO CHANGEOVER is first selected, the fan will operate at very low speed for about one minute while the unit
determines the current conditions of the room and accordingly selects the proper operation mode.
● When the air conditioner has adjusted your room’s temperature to near the thermostat setting, it will begin monitor opera-
tion. In the monitor operation mode, the fan will operate at low speed. If the room temperature subsequently changes, the
air conditioner will once again select the appropriate operation (Heating, Cooling) to adjust the temperature to the value set
in the thermostat. (The monitor operation range is ±4 °F relative to the thermostat setting.)
● If the mode automatically selected by the unit is not satisfactory, see page 3 for instructions on changing the mode setting
(HEAT, COOL, FAN).
* Heating:
● Use to warm your room.
● When Heating mode is selected, the air conditioner will operate at very low fan
speed for about 3 to 5 minutes, after which it will switch to the selected fan set-
ting. This period of time is provided to allow the indoor unit to warm up before
begin full operation.
● When the room temperature is very low, frost may form on the outside unit, and
its performance may be reduced. In order to remove such frost, the unit will
automatically enter the defrost cycle from time to time. During defrosting (see
page 15), the heating mode will be temporarily interrupted. DEFROST will be
shown on the remote controller display.
Cooling:
● Use to cool your room.
Fan:
● Use to circulate the air throughout your room.
* During Heating mode:
Set the thermostat to a temperature set-
ting that is higher than the current room
temperature. The Heating mode will not
operate if the thermostat is set lower than
the actual room temperature.
During Cooling mode:
Set the thermostat to a temperature set-
ting that is lower than the current room
temperature. The Cooling mode will not
operate if the thermostat is set higher than
the actual room temperature (in Cooling
mode, the fan alone will operate).