Frigidaire L0806995 Air Conditioner User Manual


 
installation instructions
For Heavy Duty (FAS Models) and
Median (FAM Models) Air Conditioners
Please read ALL instructions before installing. Two people are
recommended to install this product. If a new electrical outlet
is required, have the outlet installed by a qualified electrician
before installing unit, See#5 in Preliminary Instructions
following.
Prelimi nary instru ctions
Do the following before starting to install unit. See illustrations
below.
Check dimenstions of your unit to determine model type:
Heavy duty (FAS) Median (FAM)
Unit Height: 18,5/8" 17.5/8"
Unit Width: 261/2" 231/2"
Min. Window Opening: 19" 181/2"
Min. Window Width: 31" 26 Vj'
Max. Window Width: 43" 40 V2"
1. Check window opening size- the mounting parts furnished
with this air conditioner are made to install in a wooden
sill double-hung window.The standard parts are for
window dimensions listed above.Open sash to a minimum
of 1g"(483mm). (FIG. 1)
2. Check condition of window- all wood parts of window
must be in good shape and able to firmly hold the needed
screws.if not, make repairs before installing unit.
FIG. 1
_1SASH
19" MIN
1/2" MIN
STORM WINDOW FRAME OR
OTHER OBSTRUCTION
FOAM GASKET
WASHERHEAD
LOCKENG SCREW_._._ X
ASSEMBLY
(LEFT)
SIDE RETAENER J
BRACKET
3. Check your storm windows= if you storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown in FIG.2, or by removing
storm window while room air conditioner is being installed.
(continued)
FIG. 2
// SASH
f
19" MIN
1112
STORM WINDOW FRAME OR WITH TWO NAILS OR
OTHER OBSTRUCTION SCREWS.
P/N 6612990 1162