Frigidaire KG7 Furnace User Manual


 
Davies Supply Group Ltd.
Calgary (800) 661-1346 Lethbridge (877) 595-7707 Saskatoon (877) 355-3377
(403) 244-2161 (403) 381-7707 (306) 933-2433
Furnaces
A40
22/04/11
WARRANTY ON PHILCO FURNACES
Warranty Details:
Lifetime Heat Exchanger and 10 years on all parts when product is
registered, 1 year Heat Exchanger and 1 year parts when not registered
1 Year Comfort Quality Pledge:
Replacement of the entire unit if Heat Exchanger fails within the first year
of operation to the original owner
Warranty Registration:
Register your system within 60 days of installation
Philco KG7 Series Gas Furnace Features & Benefits
Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct
vent (2 pipe) system
100% fired and tested: All units and each component are tested on the manufacturing line
Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils
Best packaging in the industry: Unique corner post design assure product will arrive to the homeowner dent free
Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat
exchanger assures long life
30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower settings
(60, 90, 120 and 180 seconds)
30 second post purge: Increases life of heat exchanger
Hot surface igniter: Innovative application of an appliance igniter. Utilizes proven Smartlite® technology
Color coded wire harness: Designed to fit the components, all with quick connect fittings for ease of service
High static blowers: All models equipped with high static blowers
90 second fixed cooling cycle blower off delay (TDR): Increases cooling performance when matched with a coil
LP convertible: Simple burner orifice and regulator spring change for easy of convertibility
Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2
lights in combination to indicate all other fault codes
Integrated control board: Incorporates connections for electronic air clear and humidifier
Two piece door design: Enhances furnace appearance and uses captured screw to prevent loosing door screws
Sealed vestibule: Reduces burner and inducer sound levels
Extended flush jacket: Jacket provides an "appliance appearance"
CSA certified design
115V, 60Hz. Gas connections are 1/2" NPT
C & L are Energy Star rated