Frigidaire EA108T Air Conditioner User Manual


 
WALL SLEEVE INSTALLATION INSTRUCTIONS FOR
FRIGIDAIRE
THRU-THE WALL AIR CONDITIONERS
READ AND SAVE THESE INSTRUCTIONS
To avoid risk of personal injury, property damage, or
product damage duetotheweightofthisdeviceand
sharp edges that may be exposed:
• Air conditioners covered in this manual pose an
excessive weight hazard. Twoormorepeopleare
needed to moveand install theunit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
Carefully inspect location where air conditionerwill
be installed. Be sure it will support theweight of the
unit overan extended period of time.
Handle air conditioner with care. Wearprotectivc
gloves whenever liftingor carrying theunit. AVOID
the sharp metalfins of front and rearcoils.
Make sure air conditioner does not fall durin(
installation.
For New Construction install Frigidaire Wall Sleeve
(Part EA108T).
Remove old air conditionerand inspect sleeve forthe
following:
Installation-Make sure that sleeve is securely
installed and in sound structural condition.
Dimensions-Measure the size to make sure the air
conditioner will fit.
Slope-There should be a rearward slope for
condensate to drain from the rear of the sleeve.
Check against Fig.A.
1/4" to 5/16"
Wall Sleeve _ _E
REAR k FRONT
VEL
UNIT
Fig. A
Manufacturer-So the method of installation can be
determined.
If the installation and slope are suspect, then removal
and correct installation of a Frigidaire WallSleeve
(Part EA108T), is recommended.
Check the contents of the accessories supplied with
our air conditioner as shown below:
Number
1
2
3
4
5
6
7
8
9
10
11
Part name
Top/Bottom Trim Frame
Side Trim Frame
Plastic Mesh
Tapered Spacer Block Board
Tapered Spacer Block
Vertical Foam
Horizontal Foam
Vertical Trim Foam
Horizontal Trim Foam
Screw
Washer
QTY.
2
2
1
2
1
2
2
2
2
4
4
P/N: 819042236-01