Frigidaire DH300EY5 Dehumidifier User Manual


 
3.2.8
FAN AND MOTOR
1. Turn the nut left and full out the Fan by hands
carefully.
2. Remove 2 screws that fasten Heat Exchange.
3. Lift the H/E and open the H/E around 45 degree
clockwise carefully. (See Figure 22)
4. Unfasten 3 screws that secure the Motor and earth
wire. (See Figure 23)
5. Remove the Motor.
3.2.9
SHROUD AND DRAIN PAN
1. Discharge the refrigerant by using a refrigerant
Recovery System.
2. After purging the unit completely, unbrace the
Discharge and the Suction tube connected
compressor carefully.
3. Remove 2 screws that fasten the H/E.
4. Unfasten 2 screws that secure the shroud on the
sides and then lift shroud from the drain pan.
(See Figure 24)
5. Unfasten 2 screws that secure the drain pan to
base pan. (See Figure 25)
6. Pull the drain pan backward then take it up from the
base. (See Figure 25)
16
Figure 25
Figure 22
Figure 23
Figure 24