7
920-075-08
3) Electrical Data
Sample Name plate (see your chassis name plate)
Electrical Data
Voltage ( V) 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208 230/208
LRA - Comp. (A) 21 21 21 24.0 24.0 24.0 47 47 47
Cooling Current (A) 4.4/4. 9 4.4/4. 9 4.4/4.9 5.5/6.1 5.5/6.1 5.5/6.1 9.2/10.2 9.2/10.2 9.2/10.2
MIN. Ckt. Amps (A) 15 20 30 15 20 30 15 20 30
Power Connection HARD WIRED HARD WIRED HARD WIRED
V(E,H)A09K25
V(E,H)A09K34
V(E,H)09K50
V(E,H)A12K25
V(E,H)A12K34
V(E,H,)A12K50
V(E,H)A18K25
V(E,H)A18K50
V(E,H)A18K34
Model
MODEL NO 1
SERIAL NO *
FRIEDRICH AIR CONDITIONING CO.
SAN ANTONIO, TEXAS
VOLTS: 24,33,34
VOLTAGE RANGE: 255-197
REFRIG CHARGE: 7 OZS. R22
DESIGN PRESSURE: 575 PSIG HS / 150 PSIG LS
COOLING: BTU/HR 8
SEER: 10 COP: 16
HEAT PUMP BTU/HR: 14
TOTAL COOLING AMPS: 9
TOTAL ELEC. HEAT AMPS: 15
ELECTRIC HEAT WATTS: 18
FOR PERMANENTLY CONNECTED UNITS ONLY:
COMP'. PLA 11 LRA 12
MOTOR: FLA 13 HP 19
HEATER AMPS: 17
MIN. CKT AMP ~0 USE ~1 MAX. TIME DELAY FUSE
OR HACR TYPE CIRCUIT BREAKER.
GENERAL UNIT INFORMATION:
MAX OUTLET AIR TEMPERATURE: 2OO'F
MAX EXTERNAL STATIC PRESSURE ELECTRIC
HEAT'..5 IN. WATER
"O" CLEARANCE TO COMBUSTIBLE MATERIAL
USE ON SINGLE OUTLET CIRCUIT ONLY
ELECTRICAL SHOCK AND
MOVING PARTS HAZARD
CAN CAUSE INJURY OR
DEATH
PULL OUT DISCONNECT
HEAD LOCATED ON THE
FRONT OF THIS UNIT TO
DISABLE POWER BEFORE
SERVICING.
LISTED
120524
HEATING AND
COOLING EQUIPMENT
APPLICABLE PATENTS:
US 6,065,296
NY MEA NO.: 295-00-E
USE ONE OF THE
FOLLOWING ITEMS
FROM EACH CATEGORY
TO COMPLETE THE
ASSEMBLY
WALL PLENUM:
VPAWP1 -8
VPAWP1 -14
OUTDOOR GRILLE
VPAL2
INDOOR GRILLE
VPRG1
VPRG2
VPRG5
SAMPLE
WARNING
Important: all 208/230v chassis must be hard wired with properly sized breaker. See nameplate for specifi c chassis
electrical requirements. See page 8 - Figure 5 for unit wiring and wall thermostat wiring. See page 8 for wire size. Use
HACR type breakers to avoid nuisance trips. All fi eld wiring must be done in accordance with nec and local codes.