Page 17
FIGURE P
SECTION VI
CHASSIS INSTALLATION
STEP 1. Slide the chassis into the cabinet stopping approximately 3" from full insertion. Stuff the chassis seal gasket (Item
#14) one inch deep between the chassis and the cabinet (See Figure P). Make sure that the gasket is behind
the conduit connector (furthest from you). Push the chassis into the shell the remaining distance so that the
plastic front shrouds the front edge of the shell. Fasten the junction box mounting foot to the shell with the sheet
metal screw.
NOTE: Field wiring must be provided to this junction box in accordance with NATIONAL ELECTRIC CODE
ARTICLE 501. Field and equipment grounds are to be terminated at the post in the junction box with
the green screw provided. Equipment power leads are to be connected with the field supply by means
of wire nuts (not provided). Install the gasket and cover plate onto the junction box.
CHASSIS SEAL
GASKET