Friedrich RT5 Thermostat User Manual


 
11
Symptom Remedy
No display For Hardwired Installation
Check for 24 VAC at thermostat; display is blank when 24 VAC is not present
For Battery Installation
Display is blank when batteries are drained or installed incorrectly
System fan does not come on
properly
Verify wiring is correct
Check position of gas/electric switch
Thermostat turns on and off too
frequently
Adjust temperature differential (see “Temperature Differential,” Step 3, Page 6)
Fan runs continuously Check fan On/Auto switch, ON position runs indoor fan continuously
Fan operates at wrong speed Slide High/Low fan switch to correct position
Room temperature is not correct Verify wall hole is plugged with putty or insulation; calibrate thermostat (see “Con guration,”
Step 6, Page 8)
ROOM displays Room temperature offset is not zero (see “Con guration,” Step 6, Page 8)
Status indicator Green light – Cooling operation
Red light – Heating operating
Status indicator option ON (see “Con guration,” Step 9, Page 8)
lter displays Fan run time has exceeded lter check time set in con guration (see “Con guration,” Step 8,
Page 8)
To reset counter to zero and clear
lter warning, press the and button simultaneously
for 5 seconds
Troubleshooting