TECHNICAL SERVICE DATA
VEA09K**RTL 230/208 4.2 58 22 118 156 66 9 24 151 389 33.5
VEA12K**RTL 230/208 5.2 57 23 116 158 59 12 17 141 396 32.0
VEA18K**RTL 230/208 8.1 55 25 127 180 60 12 28 135 455 48.0
VEA24K**RTL 230/208 10.0 55 25 125 170 61 10 34 135 440 65.0
VHA09K**RTL 230/208 4.1 57 23 117 155 62 12 20 155 405 39.0
VHA12K**RTL 230/208 5.3 55 25 119 165 65 15 23 145 450 42.0
VHA18K**RTL 230/208 8.2 51 29 129 190 60 14 35 133 465 45.0
VHA24K**RTL 230/208 10.6 51 29 128 174 60 12 32 140 480 74.0
¹Test Conditions: 80º F, Room Air Temperature with 50% Relative Humidity, and 95º F, Outdoor Air Temperature with 40% Relative Humidity
**Denotes Heater KW - Numbers Vary
Sub-Cooling
OPERATING
PRESSURES
SERVICE DATA
Cooling¹
INDOOR COIL
TEMPERATURE
º F
OUTDOOR COIL
TEMPERATURE
º F
Discharge Line
Temperature
º F
ELECTRICAL
RATINGS
R-410A - Oz.Voltage
Refrigerant
Charge
Supply Air
Temperature
Drop
¨
Suction DischargeAmps
Suction Line
Temperature
º F
Super Heat
TECHNICAL SERVICE DATA
41